TEMPO

Press the TEMPO button to enter a time in seconds. This is the maximum time determined by the operator to reach the setpoint.

When starting the dosage (pressing the green button of the remote unit) a countdown of the programmed duration (TEMPO) is carried out. In

the case of exceeding the TEMPO value, the symbol '' I I '' (pause) will flash on the screen and the color of the time bar will alternate between
red and green:

It is recommended to set an alert threshold assigned to one of the relay output to send the information remotely (see § Threshold).
In this case, the assigned relay will close if the setpoint is not reached at the end of the TEMPO.

Pressing the red RESET button on remote control unit, acknowledges the alarm and changes the status of the relay.
To access the following parameters, the padlock must be unlocked.

Enter the password, then press OK

FREQUENCIES

Hereafter: Details of the steps to set the frequency input:
Go to the menu ''FREQUENCY''

Measurement unit

Enter the unit of measurement through the keyboard (example: cm³)

Corresponding frequence  to 1 measurement unit

Enter the frequency corresponding to the measurement unit: Fréquence ? = for 1
Unit

Pulse value

Result of calculation from values entered in frequency and unit

Bounce-free counting

This function avoid counting any bounces of a dry contact when it is activated.
The filter blocks frequencies above 4 Hz; Use this function only for dry contact

signals with frequency Max. < 4 Hz.
Select ON to enable this function
Select OFF to disable this function (Default value: OFF)

RE

30-03-2022

M-217.05-EN-AD

217-05

/9

Counter, Totalizer, Dosing

controller

BAMOWIZ DOZ

22, Rue de la Voie des Bans · Z.I. de la gare · 95100 ARGENTEUIL

Tel

Fax

+33 (0)1 30 25 83 20

+33 (0)1 34 10 16 05

Web

E-mail

www.bamo.eu

[email protected]

INTERNATIONAL

Summary of Contents for BAMOWIZ DOZ

Page 1: ...R MANUAL RE 30 03 2022 M 217 05 EN AD 217 05 1 Counter Totalizer Dosing controller BAMOWIZ DOZ 22 Rue de la Voie des Bans Z I de la gare 95100 ARGENTEUIL Tel Fax 33 0 1 30 25 83 20 33 0 1 34 10 16 05...

Page 2: ...ONSULTATION review mode or MODIFICATION set up mode 7 SCREEN SAVER 8 SETTINGS 8 SETPOINT 8 OFFSET 9 TEMPO 9 FREQUENCIES 10 THRESHOLDS 10 TEST OF RELAYS 10 TOTALIZER RESET RE 30 03 2022 M 217 05 EN AD...

Page 3: ...m the control TECHNICAL FEATURES User interface Graphic color touch screen size 4 3 Resolution 480 x 272 pixels Languages English French German Polish Portuguese Spanish Touch screen keyboard alphanum...

Page 4: ...rol unit according the voltage to supply to the solenoid valve DIMENSIONS INSTALLATION Caution Do not drill the cabinet RE 30 03 2022 M 217 05 EN AD 217 05 4 Counter Totalizer Dosing controller BAMOWI...

Page 5: ...solenoid valve External power supply 24 to 250 V AC Or 24 V DC version Interface to the monitor External controls 24 V RE 30 03 2022 M 217 05 EN AD 217 05 5 Counter Totalizer Dosing controller BAMOWI...

Page 6: ...te within the menus ON OFF To enable ON or disable OFF settings of an entry SAVE To save the settings ESCAPE To cancel any modification on the input settings RELAY STATUS S1 S2 S3 Display relays statu...

Page 7: ...BAMOWIZ is on the sticker on side of the cabinet You can find it as well through the menu SETTINGS From the main screen go to MENU Press the padlock icon and type the last four number of S N Pressing...

Page 8: ...main display the following parameters can be entered SETPOINT Press the Value key to enter the setpoint Volume to reach OFFSET Press the OFSET key to enter the real volume passed at the time the circ...

Page 9: ...rs the padlock must be unlocked Enter the password then press OK FREQUENCIES Hereafter Details of the steps to set the frequency input Go to the menu FREQUENCY Measurement unit Enter the unit of measu...

Page 10: ...N to use pulse mode If the selection is ON enter the pulse duration in seconds in the menu Energized Enter the number of cycles required to energize the relay Threshold action To assign the threshold...

Reviews: