SAFETY INSTRUCTIONS

• Installation, commissioning and maintenance must be carried out by qualified technicians.
• Only connect the device to the voltage specified in the technical features and label.
• Disconnect all power sources from the device during interventions or maintenance tasks.
• The operation of the device must be in accordance with and strictly limited to the applications, as mentioned further on and on data-sheet.

APPLICATIONS

BAMOWIZ DOZ is a programmable counter and totalizer as well as a dosing system.
The setpoint (Dosing quantity) is permanently accessible from the main display, which makes it ideal for applications that require regular
adjustments.

It accepts pulse signals from flow sensors operating in the range of 0.04 Hz to 10 kHz

DESCRIPTION

The BAMOWIZ DOZ consists of two elements: A programmable monitor and a control unit.
The BAMOWIZ DOZ converts the frequency (input signel) into a configurable physical quantity (m³, Liter, etc.)

The graphic color touch screen facilitates settings through the menus and allows viewing of all parameters.

A dosing cycle may be started (or interrupted) from the control unit which supplies and directly controls a solenoid valve via the static output.

Start

STANDBY / RESET

Control unit

Controls of dosing start and stop can be remote from the control.

TECHNICAL FEATURES

User interface

Graphic color touch screen, size 4/3
Resolution: 480 x 272 pixels

Languages

English - French - German - Polish - Portuguese - Spanish

Touch screen keyboard, alphanumeric

Dedicated for each language

Counter, Totalizer for pulse flow sensors

Frequency input

Range from 0.04 Hz up to 10 kHz

Bounce-free counting

For dry contact (potential-free)

Relay outputs

3 N.O. contacts, to set; potential free
Pulse mode or ON/OFF mode

Adjustable thresholds

Total of 8 thresholds to set and assigned to the 3 relays

For the functions: Totalizer, counter or timer

Alarm delay

From 0 to 9999 s

Switching power

3 A / 250 V AC

Hysteresis

Adjustable from 0 to 100 %

Reset on Totalizer

Reset to zero of totalizer and number of cycles

Relay switching simulation

Manual test for each relay

1 Static output

Solenoid valve control (with an external power supply)

230 V AC; Max. 400 W
Version 24 V DC; Max. 40 Watt
Switching power: max. 40 W

Monitor, power supply

100 ... 240 V AC - 50/60 Hz

Consumption

5 VA Max.

Electrical connections

Screw terminals

Cable glands

Total: 5; PG 9

Mounting

Wall mount cabinet, IP 65 – ABS plastic

Ambient temperature limits

-10 ... +50 °C

EC Conformity: These devices meet the legal requirements of the current European Directives.

RE

30-03-2022

M-217.05-EN-AD

217-05

/3

Counter, Totalizer, Dosing

controller

BAMOWIZ DOZ

22, Rue de la Voie des Bans · Z.I. de la gare · 95100 ARGENTEUIL

Tel

Fax

+33 (0)1 30 25 83 20

+33 (0)1 34 10 16 05

Web

E-mail

www.bamo.eu

[email protected]

INTERNATIONAL

Summary of Contents for BAMOWIZ DOZ

Page 1: ...R MANUAL RE 30 03 2022 M 217 05 EN AD 217 05 1 Counter Totalizer Dosing controller BAMOWIZ DOZ 22 Rue de la Voie des Bans Z I de la gare 95100 ARGENTEUIL Tel Fax 33 0 1 30 25 83 20 33 0 1 34 10 16 05...

Page 2: ...ONSULTATION review mode or MODIFICATION set up mode 7 SCREEN SAVER 8 SETTINGS 8 SETPOINT 8 OFFSET 9 TEMPO 9 FREQUENCIES 10 THRESHOLDS 10 TEST OF RELAYS 10 TOTALIZER RESET RE 30 03 2022 M 217 05 EN AD...

Page 3: ...m the control TECHNICAL FEATURES User interface Graphic color touch screen size 4 3 Resolution 480 x 272 pixels Languages English French German Polish Portuguese Spanish Touch screen keyboard alphanum...

Page 4: ...rol unit according the voltage to supply to the solenoid valve DIMENSIONS INSTALLATION Caution Do not drill the cabinet RE 30 03 2022 M 217 05 EN AD 217 05 4 Counter Totalizer Dosing controller BAMOWI...

Page 5: ...solenoid valve External power supply 24 to 250 V AC Or 24 V DC version Interface to the monitor External controls 24 V RE 30 03 2022 M 217 05 EN AD 217 05 5 Counter Totalizer Dosing controller BAMOWI...

Page 6: ...te within the menus ON OFF To enable ON or disable OFF settings of an entry SAVE To save the settings ESCAPE To cancel any modification on the input settings RELAY STATUS S1 S2 S3 Display relays statu...

Page 7: ...BAMOWIZ is on the sticker on side of the cabinet You can find it as well through the menu SETTINGS From the main screen go to MENU Press the padlock icon and type the last four number of S N Pressing...

Page 8: ...main display the following parameters can be entered SETPOINT Press the Value key to enter the setpoint Volume to reach OFFSET Press the OFSET key to enter the real volume passed at the time the circ...

Page 9: ...rs the padlock must be unlocked Enter the password then press OK FREQUENCIES Hereafter Details of the steps to set the frequency input Go to the menu FREQUENCY Measurement unit Enter the unit of measu...

Page 10: ...N to use pulse mode If the selection is ON enter the pulse duration in seconds in the menu Energized Enter the number of cycles required to energize the relay Threshold action To assign the threshold...

Reviews: