TEST MODE
The device has an integrated test function. It can be activated as follows:
- Press the test button (at least 1 second)
- Self-check is started
- LEDs are blinking...
- Controlling the buzzer
- Checking the connection values of the corresponding probe
(correct type?, short circuit?, broken cable?)
Test passed
= the corresponding LED is lit in green
Test not passed
= the corresponding LED is blinking in green
MAINTENANCE
When used as intended, the sensor supply unit / control unit (NivOil CU) and the probes are maintenance-free.
After an alarm has been detected, the probes must also be cleaned after cleaning the light liquid separator.
The probes can be cleaned of the adhesive grease/oil film with commercially available, grease-dissolving cleaners.
Note!
Electrostatic discharging must be prevented during cleaning. Clean with a damp cloth only!
SPECIAL CHARACTERISTICS
Oil probe (NivOil OP)
The oil/light liquid layer can no longer be detected correctly, if it is mixed with other chemicals such as surfactants, emulsifiers, etc.
Sludge probe (NivOil SP)
The probe may only be used in liquids to which PVC is sufficiently resistant.