E
N
G
L
I
S
H
1 / 18
000608.1041_201102
- Before using the burner for the first time please carefully read the chapter “WARNINGS NOTES FOR
THE USER : HOW TO USE THE BURNER SAFELY” in this instruction manual, which is an integral
and essential part of the product. The works on the burner and on the esystem have to be carried
out only by competent people.
- Read carefully the instructions before starting the burner and service it.
- The system electric feeding must be disconnected before starting working on it.
- If the works are not carried out correctly it is possible to cause dangerous accidents.
BALTUR S.p.A.
Via Ferrarese 10 - 44042 CENTO (Ferrara) ITALIA
Tel. 051.684.37.11 Fax 051.685.75.27/28
(International Tel. ++39.051.684.37.11 - Fax ++39.051.683.06.86)
http://www.baltur.it - http://www.baltur.com - E-MAIL [email protected]
04/01/2010
Declaration of Conformity
We declare that our products
BPM...; BGN…; BT…; BTG…; BTL…; TBML...; Comist…;
GI…; GI…Mist; Minicomist…; PYR…; RiNOx…; Spark...;
Sparkgas...; TBG...;TBL...; TBML ...; TS…; IBR...; IB...
(Variant: … LX, for low NOx emissions)
Description:
forced air burners of liquid, gaseous and mixed fuels for residential and
industrial use meet the minimum requirements of the European Directives:
90/396/CEE ...............................................(D.A.G.)
89/336/CEE - 2004/108/CE ........................(C.E.M.)
73/23/CEE – 2006/95/CE ...........................(D.B.T.)
2006/42/CEE .............................................(D.M.)
and conform to European Standards:
UNI EN 676:2008
(gas and combination, gas side)
UNI EN 267:2002
(diesel and combination, diesel side)
These products are therefore marked:
0085
Dr. Riccardo Fava
Managing Director / CEO
INDEX
................................................................................................................................................PAGE
- Warning notes for the user ............................................................................................................... “
2
- Technical specifications.................................................................................................................... “
4
- Application of the burner to boiler - Burner connection to gas mains ............................................ “
8
- Electrical connections - Descriptions of operations ......................................................................... “
9
- Gas burner control devices .............................................................................................................. “
11
- Methane gas ignition and adjustment .............................................................................................. “
12
- Air regulation on the combustion head - Maintenance - Use of the burner ...................................... “
15
- Problem - Cause - Solution .............................................................................................................. “
18
- Electric diagram ............................................................................................................................... “
75
Summary of Contents for TBG 55
Page 2: ......
Page 75: ...75 80 000608 1041_201102...
Page 76: ...76 80 000608 1041_201102...
Page 79: ...79 80 000608 1041_201102...