TECHNICAL SPECIFICATIONS
MODEL
TBG 45 P
TBG 60P
MAXIMUM NATURAL GAS HEAT POWER
kW
450
600
MINIMUM NATURAL GAS HEAT POWER
kW
100
120
¹) NATURAL GAS EMISSIONS
mg/kWh
Class 3
Class 3
OPERATION
Two-stage
Two-stage
NATURAL GAS TRANSFORMER 50 Hz
26 kV - 40 mA - 230/240 V
26 kV - 40 mA - 230/240 V
NATURAL GAS TRANSFORMER 60 Hz
26 kV - 40 mA - 220/230 V
26 kV - 40 mA - 230/240 V
MAXIMUM NATURAL GAS HEAT RATE
Stm³/h
48
63.5
MINIMUM NATURAL GAS HEAT RATE
Stm³/h
11
12.7
MAXIMUM NATURAL GAS PRESSURE
hPa (mbar)
360
360
NATURAL GAS MINIMUM PRESSURE
hPa (mbar)
12
20
PROPANE GAS MAXIMUM THERMAL POWER
kW
450
600
PROPANE GAS MINIMUM THERMAL POWER
kW
100
120
PROPANE GAS MAXIMUM HEAT CAPACITY
Stm³/h
18
24.5
PROPANE GAS MINIMUM HEAT CAPACITY
Stm³/h
4
4.9
PROPANE GAS MAXIMUM PRESSURE
hPa (mbar)
360
360
PROPANE GAS MINIMUM PRESSURE
hPa (mbar)
30
29
²)PROPANE EMISSIONS
mg/kWh
Class 3
Class 3
50 Hz FAN MOTOR
kW
0.5
0.74
60Hz FAN MOTOR
kW
0.5
0.65
ABSORBED ELECTRICAL POWER* 50Hz
kW
0.68
0.9
ABSORBED ELECTRICAL POWER* 60Hz
kW
0.68
0.83
50 Hz POWER SUPPLY VOLTAGE
1N~ 230V ± 10%
3N~ 400V ± 10%
60 Hz POWER SUPPLY VOLTAGE
1N~ 220V ± 10%
3N~ 380V ± 10%
DEGREE OF PROTECTION
IP 44
IP 44
FLAME DETECTOR
IONISATION PROBE
IONISATION PROBE
EQUIPMENT
LME22..
LME22..
AIRFLOW REGULATION
electric servomotor
electric servomotor
SOUND PRESSURE**
dBA
76
76
SOUND POWER***
dBA
88
88
WEIGHT WITH PACKING
kg
40
42
WEIGHT WITHOUT PACKING
kg
32
34
Calorific power lower than reference conditions 15° C, 1013 hPa (mbar):
Natural gas: Hi = 9.45 kWh/Stm³ = 34.02 MJ/Stm³
Propane gas: Hi = 24.44 kWh/Stm³ = 88.00 MJ/Stm³
For different types of gas and pressure values, please contact our sales department.
Minimum gas pressure, depending on the type of gas train used for obtaining max. flow rate with null pressure in the combustion chamber.
* Total absorption at start with ignition transformer on.
The measurements have been carried out in accordance with EN 15036 - 1 standard.
** The acoustic pressure measured with burner operating at maximum rated thermal output refers to the manufacturer's laboratory
environment conditions and cannot be compared to measurements carried out in different locations.
*** Acoustic power was obtained characterizing the manufacturer's laboratory with a sample source; this measurement has a class 2
accuracy (engineering class) with a standard deviation of 1.5 dB(A).
CO emissions, natural gas/propane ≤ 100 mg/kWh
¹) NATURAL GAS EMISSIONS
Classes defined according to Standard EN 676.
Class
NOx emissions in mg/kWh - natural
gas
1
≤ 170
2
≤ 120
3
≤ 80
²) PROPANE EMISSIONS
Classes defined according to Standard EN 676.
Class
NOx emissions in mg/kWh - propane
gas
1
≤ 230
2
≤ 180
3
≤ 140
Summary of Contents for TBG 45 P
Page 2: ......
Page 34: ...ITALIANO 32 34 0006160178_201711 SCHEMI ELETTRICI ...
Page 35: ...ITALIANO 33 34 0006160178_201711 ...
Page 68: ...ENGLISH 32 34 0006160178_201711 WIRING DIAGRAMS ...
Page 69: ...ENGLISH 33 34 0006160178_201711 ...
Page 71: ......