21 / 30
0006081265_201212
ENGLISH
10 ERROR OVERVIEw
Error display
0 x 01
ERROR CODE
Space
F
internal
error
Error description
Solution
MPA 51xx
O
System fault
Replace the equipment
ID error
internal
error
Error description
Possible error cause
10.1 Processor 2 errors
F1 the display flashes
●
No bus connection to processor 1
? TWI bus line locked out due to a faulty external bus, for
example faulty VisionBox....
F2 the display flashes
Wrong display
? The MPA 51xx has been connected to the AM03 display (only
for MPA 51). Correct: use AM08 or AM09
10.2 Basic system errors (from 0x01 to 0x3F)
0x01
●
ERROR_INTERRUP_CYCL_STATE FRAME
0x02
●
ERROR_WD_ACTIVATION
0x03
●
ERROR_WD_HARDWARE
0x04
ERROR_RESET_UNAUTHORISED
? more than 5 resets in the last 15 minutes; solution: wait or
perform prolonged reset
0x05
●
ERROR_ROM_TEST
0x06
●
ERROR_RAM_TEST
0x07
●
ERROR_PIN SHORTCIRCUIT
0x08
●
ERROR_STACK_OVERFLOW
0x09
●
ERROR_PROGRAMMING
0x0A
●
VARIABLE_ERROR
0x0B
●
ERROR_ERROR IN TAB PROCESS
0x0C
●
Free
0x0D
●
ERROR_CPU_TEST
0x0E
●
ERROR_EEPROM_PARAMETERS
0x0F
●
ERROR_TEST_ADDRESS
0x10
●
Free
0x11
ERROR_UNDERVOLTAGE
? The permitted lower voltage limit has been briefly exceeded
0x12
ERROR_LOSS OF NETWORK
? The supply voltage has been interrupted during the start up,
operation or adjustment switch off.
0x13
ERROR_WD_STATUS
? The safety chain is not at zero
0x14
●
ERROR_TEST_SEGMENT
0x15
●
ERROR_TEST_SFR_REGISTER
0x16
ERROR_TWI_COMMUNICATION
? A TWI bus user has been connected or disconnected
from the bus while the MPA was disconnected from
the network. Solution: connect or disconnect the TWI
bus users only with the power supply disconnected.
? The are too many users connected to the TWI bus or the TWI
cable is subject to EMC disturbances. Solution: use wires that
are shorter or reduce the number of users
0x17
●
ERROR_OVERCHARGED_STATE FRAME
0x18
ERROR_ExTERNAL_APPLICATION
A user has caused an external switch off for example selecting
the "Switch off" function in the PC software of the VisionBox
0x19
●
Free
0x1A
●
ERROR_SWWD_DURING_INITIALISATION
0x1B
●
ERROR_BUFFER OVERFLOW
Summary of Contents for BPM 140 EVO
Page 2: ......
Page 27: ...27 30 0006081265_201212 ITALIANO SCHEMI ELETTRICI...
Page 29: ...29 30 0006081265_201212 ITALIANO...
Page 48: ...20 30 0006081265_201212 ENGLISH...
Page 55: ...27 30 0006081265_201212 ENGLISH WIRING DIAGRAMS...
Page 57: ...29 30 0006081265_201212 ENGLISH...
Page 83: ...27 30 0006081265_201212 DEUTSCH SCHALTPLAN...
Page 85: ...29 30 0006081265_201212 DEUTSCH...
Page 111: ...27 30 0006081265_201212 P O L S K I SCHEMATY ELEKTRYCZNE...
Page 113: ...29 30 0006081265_201212 P O L S K I...
Page 115: ......