background image

- 7 -

Regulator Display Modes

 - 

Short Display/Long Display

The regulator’s three digit alphanumeric LED display provides a scrolling view of charging status. Under normal operation, 
the display will indicate the following:

Indicates Balmar.

Indicates Model ARS-5

Indicates regulator’s default Universal Factory Program. Display will vary based on program selected. 

Indicates the regulator’s Belt Load Manager setting. Ranges from b-0 to b-9.

Indicates stage of charge. “b” indicates bulk. “A” indicates absorption. “F” indicates float.

Indicates system Battery Voltage. Followed by actual voltage reading.

Indicates Calculated voltage (target voltage based on preset program levels). Followed by voltage reading.

Indicates Battery temperature. Followed by NC (not connected), or temperature in celsius.

Indicates Alternator temperature. Followed by NC (not connected), or temperature in celsius.

In addition to the information provided in the basic display shown above, the ARS-5 long display provides the following 
data. The long display is accessed during basic programming, which will be discussed in the next section of the manual. 

Indicates the percentage of field output to the alternator. The higher the percentage, the greater the output.

Indicates regulator’s software revision code.

Indicates regulator circuit board temperature. Followed by degrees celsius.

Indicates, in millivolts per degree C per cell, voltage compensation for battery temperature.

Indicates overall regulator hours. Followed by hours (by tenths) and hours in excess of 100.

Indicates field threshold; bulk to absorption to float. Factory set at 65%. Adjust in Advanced Programming.

Indicates field threshold from float to absorption. Factory set at 65%.  Adjust in Advanced Programming.

Indicates system advisory codes. Individually numbered codes are defined below.

The following advisory codes can be used to determine possible system errors or to identify specific operational modes. 
Note that E codes are cumulative and will be held in memory until cleared. Codes can be cleared by entering dSP and 
letting it save. Display settings DO NOT need to be changed. See basic programming for more info.

BATTERY TEMP. SENSOR CABLE 
SHORTED

BATTERY TEMP. SENSOR CABLE 
OPEN OR NOT FOUND

ALTERNATOR TEMP. SENSOR 
CABLE SHORTED

ALTERNATOR TEMP. SENSOR 
CABLE OPEN OR NOT FOUND

BATTERY EXCEEDS 55˚C. 
FACTORY DEFAULT

ALTERNATOR TEMPERATURE 
EXCEEDS 107˚C

VOLTAGE REGULATOR 
EXCEEDS 90˚C

BATTERY VOLTAGE BELOW 
12.5 VOLTS

BATTERY VOLTAGE BELOW 
10.5 VOLTS 

BATTERY TEMP EXCEEDS 
USER ADJUSTED VALUE

BATTERY VOLTAGE 
EXCEEDS 16 VOLTS

FIELD VOLTAGE TOO HIGH.

STATOR VOLTAGE TOO HIGH.

SMALL ENGINE MODE IS IN 
OPERATION

BELT LOAD MANAGER IS IN 
OPERATION

B A L

F E

E 1 0

E 4 0

- b -

H r

E 1 4

E 3 4

E 5 2

U F P

S P

E 2 4

E 4 2

C v

F F L

A - 5

r 3. 8

E 1 1

E 2 2

E 4 1

bv

F b A

E 1 5

E 2 0

E 3 5

b - 0

S L P

E 3 0

E 5 1

B 1

E

A L

Summary of Contents for ARS-5

Page 1: ...Balmar ARS 5 provides precise voltage control for Bal mar high output 12 volt alternators and other externally reg ulated P type positive field alternators the ARS 5 features user selectable programs...

Page 2: ...nd readability of the display The regulator wiring harness is 54 inches long providing a three to four foot radius for mounting Ample airflow is essential for the regulator s proper operation Ensure t...

Page 3: ...CONNECTED TO THE APPRO PRIATE REGULATOR TERMINAL BAT TEMP 6 For use with optional Battery Tem perature Sensor MC TS B STATOR IN 7 Connect to WHITE wire included in regu lator wiring harness TACHOMETE...

Page 4: ...t provides regulated current to control alternator output The wire is included in the wiring harness Ford style plug and is pre connected at the regulator At the other end of the wire you ll find eith...

Page 5: ...dible indicator when the regulator monitors the following conditions Low system voltage high system voltage high alternator temperature high battery temperature temperature conditions are only indicat...

Page 6: ...section for adjustment instructions Soft Ramp Gently increases voltage to bulk preset levels based on battery program selected 2 Bulk Charge The most aggressive of the charging stages Voltage is held...

Page 7: ...oard temperature Followed by degrees celsius Indicates in millivolts per degree C per cell voltage compensation for battery temperature Indicates overall regulator hours Followed by hours by tenths an...

Page 8: ...logies Universal Default UFP Deep Cycle Flooded FdC gel gEL AGM AgL and Optima spiral wound batteries OPS Programming can be done whenever the regulator is active System voltage must be greater than 1...

Page 9: ...ntry into the Belt Load Manager is indicated by 2 the bEL display on the regulator s LED If you don t wish to adjust the battery programming TOUCH HOLD the RED dot when the regulator is activated 3 RE...

Page 10: ...egulator provides a ground signal on the dash lamp terminal when the following conditions occur low battery volt age 12 7V high battery voltage 15 5V high battery temperature 52 C or high alternator t...

Page 11: ...ming mode The Advanced Programming Modes are as follows Start Delay Controls time from regulator activation to start of charging Factory preset at one second Adjustable to a maximum of 999 seconds To...

Page 12: ...sed to determine field output required to maintain calculated charging mode Factory set at 65 field output Raising FbA shortens calculated bulk charge time Lowering FbA increases calculated bulk charg...

Page 13: ...ure Sensor cable is being used replace the female termi 1 nal connectors on the cable with Multi Stack Connectors Ancor Part 230612 Install a standard ON OFF switch in a location that s easily reached...

Page 14: ...ests provide an opportunity to isolate the alternator regulator and wir ing harness in order to determine the problem source In order to perform these tests you will need an independent DC meter prefe...

Page 15: ...at the rear bearing initiate the following test With the key off and the engine off remove the large harness plug from the regulator Insert the end of a short length of electrical wire to the RED conn...

Page 16: ...ed in shipment in route to BALMAR for repair BALMAR assumes no responsibility for consequential damage or loss or expense arising from these products or any labor required for service or repair BALMAR...

Reviews: