background image

CAUTIOn:

 The following instructions are intended for use by experienced marine 

electrical  installers.  If  you  are  not  experienced  at  installing  electrical  system 
components, we recommend the use of a qualified marine electrical technician.

Regulator Installation

The following information is intended to provide the installer with the 
basic information required to complete installation. This section of the 
installation manual will deal with mounting, wiring connections and ba-
sic programming for battery type. Additional information regarding ad-
vanced programming adjustments and troubleshooting are addressed 
later in the manual.

Unpacking The Box

Your  ARS-5-H regulator kit is packaged with the
following items:

 ARS-5 regulator

• 

54” wiring harness

• 

Magnetic programming tool

• 

Installation and operation manual

• 
If any of the listed items is not included with your regulator kit, call our customer service department at 360-435-6100. 
Please note -- if your regulator box is marked  ARS-5, without the “H” designation, your kit will not include the wiring har-
ness. 

Locate And Mount The Regulator

Choosing  a  mounting  location  for  your  voltage  regulator  should  be  deter-
mined based on the following factors; distance from alternator, distance from 
inverters,  transmitters  and  other  sources  of  RF  noise,  convenient  access 
and readability of the display. The regulator wiring harness is 54 inches long, 
providing a three to four foot radius for mounting. Ample airflow is essential 
for the regulator’s proper operation. Ensure that the regulator is free from 
obstructions that restrict air movement around or below the regulator’s alu-
minum heat sink. While the regulator is designed to operate safely in condi-
tions typical of a marine engine compartment, the regulator may be better 
protected, and easier to use and monitor if mounted outside of the engine 
compartment. 
Should it be necessary to install the regulator further than 54 inches from 
the alternator, ensure that any wire extensions are properly connected, as 
resistance  in  the  harness  wiring  can  affect  charging  efficiency.  If  harness 
length must reach beyond approximately eight feet, replace the RED power 
BLACK ground and BLUE field wires with larger gauge wire that’s sized to 
ensure voltage drop < 3%.

Basic Wiring Installation

The regulator’s wiring harness includes five wires required for standard 
installation. Four of those wires are connected to the regulator via a 
Ford-style plug connector that’s pre-installed on the regulator. These 
wires include the Ground (BLACK), Power (RED), Ignition (BROWN) 
and Field (BLUE). Plug is shown at right. 
In addition, the harness includes a separate Stator (WHITE) wire. The 
proper terminal connection points for this, and additional wiring connec-
tions, are illustrated on the pin location legend shown and discussed on 
the following pages.      

- 2 -

Summary of Contents for ARS-5

Page 1: ...Balmar ARS 5 provides precise voltage control for Bal mar high output 12 volt alternators and other externally reg ulated P type positive field alternators the ARS 5 features user selectable programs...

Page 2: ...nd readability of the display The regulator wiring harness is 54 inches long providing a three to four foot radius for mounting Ample airflow is essential for the regulator s proper operation Ensure t...

Page 3: ...CONNECTED TO THE APPRO PRIATE REGULATOR TERMINAL BAT TEMP 6 For use with optional Battery Tem perature Sensor MC TS B STATOR IN 7 Connect to WHITE wire included in regu lator wiring harness TACHOMETE...

Page 4: ...t provides regulated current to control alternator output The wire is included in the wiring harness Ford style plug and is pre connected at the regulator At the other end of the wire you ll find eith...

Page 5: ...dible indicator when the regulator monitors the following conditions Low system voltage high system voltage high alternator temperature high battery temperature temperature conditions are only indicat...

Page 6: ...section for adjustment instructions Soft Ramp Gently increases voltage to bulk preset levels based on battery program selected 2 Bulk Charge The most aggressive of the charging stages Voltage is held...

Page 7: ...oard temperature Followed by degrees celsius Indicates in millivolts per degree C per cell voltage compensation for battery temperature Indicates overall regulator hours Followed by hours by tenths an...

Page 8: ...logies Universal Default UFP Deep Cycle Flooded FdC gel gEL AGM AgL and Optima spiral wound batteries OPS Programming can be done whenever the regulator is active System voltage must be greater than 1...

Page 9: ...ntry into the Belt Load Manager is indicated by 2 the bEL display on the regulator s LED If you don t wish to adjust the battery programming TOUCH HOLD the RED dot when the regulator is activated 3 RE...

Page 10: ...egulator provides a ground signal on the dash lamp terminal when the following conditions occur low battery volt age 12 7V high battery voltage 15 5V high battery temperature 52 C or high alternator t...

Page 11: ...ming mode The Advanced Programming Modes are as follows Start Delay Controls time from regulator activation to start of charging Factory preset at one second Adjustable to a maximum of 999 seconds To...

Page 12: ...sed to determine field output required to maintain calculated charging mode Factory set at 65 field output Raising FbA shortens calculated bulk charge time Lowering FbA increases calculated bulk charg...

Page 13: ...ure Sensor cable is being used replace the female termi 1 nal connectors on the cable with Multi Stack Connectors Ancor Part 230612 Install a standard ON OFF switch in a location that s easily reached...

Page 14: ...ests provide an opportunity to isolate the alternator regulator and wir ing harness in order to determine the problem source In order to perform these tests you will need an independent DC meter prefe...

Page 15: ...at the rear bearing initiate the following test With the key off and the engine off remove the large harness plug from the regulator Insert the end of a short length of electrical wire to the RED conn...

Page 16: ...ed in shipment in route to BALMAR for repair BALMAR assumes no responsibility for consequential damage or loss or expense arising from these products or any labor required for service or repair BALMAR...

Reviews: