background image

www.balluff.com

2

Technical data

Pressure rating (when installed in 

hydraulic cylinders)

Operating pressure:

1000 bar

Pressure peaks:

1350 bar

Nominal length

25 to 2000 mm

Diameter of outer rod

12.7 mm

Outer rod wall thickness

3.25 mm

Flange/outer rod material

HP 160

Weight (depends on length)

2.5 kg/m

Installation

NOTICE!

Interference in function

Improper installation can compromise the function of the 
transducer and result in increased wear.

The mounting surface of the transducer must make 

 

f

full contact with the mounting surface.
The bore must be perfectly sealed (O-ring/flat seal).

 

f

Only use the proper nut for the fastening screw 

thread. Firmly tighten the transducer with a 

maximum torque of 290 Nm.

If installing horizontally with nominal lengths > 500 mm, we 

recommend tightening the outer rod at the end or 

supporting it.

If installed in a hydraulic cylinder, the magnet may not 

scrape against the outer rod. Minimum bore diameter in 

the support piston:

Tube diameter

Bore diameter

12.7 mm

At least 18 mm

Mounting hole M22×1.5 per ISO 6149 O-ring 19.3×2.2

0.2

23.8+0.1

2.4+0.4

The transducer comes with an M22×1.5 (ISO) mounting 

thread. Depending on the version, a mounting hole must 

be made before assembly.

No. 868774 E 

.

 E

dition 

1103

; Subject to modification.

 Replaces edition 

0910

.

english

Startup

  DANGER

Uncontrolled system movement

When starting up, if the position measuring system is 
part of a closed loop system whose parameters have not 
yet been set, the system may perform uncontrolled 
movements. This could result in personal injury and 
equipment damage.

Persons must keep away from the system's 

 

f

hazardous zones.
Startup must be performed only by trained technical 

 

f

personnel.
Observe the safety instructions of the equipment or 

 

f

system manufacturer.

Check connections for tightness and correct polarity. 

1. 

Replace damaged connections.
Turn on the system.

2. 

Check measured values and adjustable parameters 

3. 

(especially after replacing the transducer or after 

manufacturer repairs). Re-adjust the transducer, if 

necessary.

Operating notes

Check the function of the transducer and all associated 

 

components on a regular basis.

Take the position measuring system out of operation 

 

whenever there is a malfunction.

Secure the system against unauthorized use.

 

Ordering code

BTL5-...-CD-...

High-pressure, metric fastening screw thread 

M22x1.5, rod diameter 12.7 mm

BTL7-...-CD-...

High-pressure, metric fastening screw thread 

M22x1.5, rod diameter 12.7 mm

BTL5/7-...-CD-...

Micropulse Transducer - Rod Style

Summary of Contents for Micropulse BTL5 Series

Page 1: ...BTL5 7 CD deutsch Kurzanleitung english Condensed guide fran ais Notice r sum e italiano Istruzioni brevi espa ol Instrucciones breves...

Page 2: ...iche Betriebsanleitungen erhalten Sie im Internet unter www balluff com downloads btl5 bzw www balluff com downloads btl7 oder per E Mail bei service balluff de Weitere Informationen insbesondere zu S...

Page 3: ...g muss vor der Montage das Einschraubloch gefertigt werden Nr 868774 D Ausgabe 1103 nderungen vorbehalten Ersetzt Ausgabe 0910 deutsch Inbetriebnahme gefahr Unkontrollierte Systembewegungen Bei der In...

Page 4: ...n be downloaded from the Internet at www balluff com downloads btl5 or www balluff com downloads btl7 or requested via e mail from service balluff de Further information particularly on the interfaces...

Page 5: ...Depending on the version a mounting hole must be made before assembly No 868774 E Edition 1103 Subject to modification Replaces edition 0910 english Startup Danger Uncontrolled system movement When s...

Page 6: ...d utilisation d taill es sur le site Internet www balluff com downloads btl5 ou www balluff com downloads btl7 ou sur demande par courriel service balluff de Vous trouverez de plus amples informations...

Page 7: ...lon la version le trou de vissage doit tre r alis avant le montage N 868774 F dition 1103 Sous r serve de modifications Remplace l dition 0910 fran ais Mise en service danger Mouvements incontr l s du...

Page 8: ...indirizzo www balluff com downloads btl5 o www balluff com downloads btl7 o inviare un e mail a service balluff de Per ulteriori informazioni in particolare sulle interfacce e sul collegamento elettr...

Page 9: ...ispettivo foro di avvitamento N 868774 I Edizione 1103 Con riserva di apportare modifiche Sostituisce l edizione 0910 italiano Messa in funzione pericolo Movimenti incontrollati del sistema Durante la...

Page 10: ...w balluff com downloads btl5 o www balluff com downloads btl7 o por correo electr nico escribiendo a service balluff de En el correspondiente manual de instrucciones encontrar m s informaci n relativa...

Page 11: ...3 reservado el derecho a modificaciones Sustituye a la edici n 0910 espa ol Puesta en servicio Peligro Movimientos incontrolados del sistema El sistema puede realizar movimientos incontrolados durante...

Page 12: ...uff balluff de Global Service Center Germany Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Phone 49 7158 173 370 Fax 49 7158 173 691 service balluff de US Service Center USA Balluff Inc 8125 H...

Reviews: