Technical data
Pressure rating (when installed in
hydraulic cylinders)
Operating pressure:
1000 bar
Pressure peaks:
1350 bar
Nominal length
25 to 2000 mm
Diameter of outer rod
12.7 mm
Outer rod wall thickness
3.25 mm
Flange/outer rod material
HP 160
Weight (depends on length)
2.5 kg/m
Installation
NOTICE!
Interference in function
Improper installation can compromise the function of the
transducer and result in increased wear.
The mounting surface of the transducer must make
f
full contact with the mounting surface.
The bore must be perfectly sealed (O-ring/flat seal).
f
Only use the proper nut for the fastening screw
thread. Firmly tighten the transducer with a
maximum torque of 290 Nm.
If installing horizontally with nominal lengths > 500 mm, we
recommend tightening the outer rod at the end or
supporting it.
If installed in a hydraulic cylinder, the magnet may not
scrape against the outer rod. Minimum bore diameter in
the support piston:
Tube diameter
Bore diameter
12.7 mm
At least 18 mm
Mounting hole M22×1.5 per ISO 6149 O-ring 19.3×2.2
0.2
23.8+0.1
2.4+0.4
The transducer comes with an M22×1.5 (ISO) mounting
thread. Depending on the version, a mounting hole must
be made before assembly.
No. 868774 E
.
E
dition
1103
; Subject to modification.
Replaces edition
0910
.
english
Startup
DANGER
Uncontrolled system movement
When starting up, if the position measuring system is
part of a closed loop system whose parameters have not
yet been set, the system may perform uncontrolled
movements. This could result in personal injury and
equipment damage.
Persons must keep away from the system's
f
hazardous zones.
Startup must be performed only by trained technical
f
personnel.
Observe the safety instructions of the equipment or
f
system manufacturer.
Check connections for tightness and correct polarity.
1.
Replace damaged connections.
Turn on the system.
2.
Check measured values and adjustable parameters
3.
(especially after replacing the transducer or after
manufacturer repairs). Re-adjust the transducer, if
necessary.
Operating notes
Check the function of the transducer and all associated
–
components on a regular basis.
Take the position measuring system out of operation
–
whenever there is a malfunction.
Secure the system against unauthorized use.
–
Ordering code
BTL5-...-CD-...
High-pressure, metric fastening screw thread
M22x1.5, rod diameter 12.7 mm
BTL7-...-CD-...
High-pressure, metric fastening screw thread
M22x1.5, rod diameter 12.7 mm
BTL5/7-...-CD-...
Micropulse Transducer - Rod Style