55
www.balluff.com
BVS HS-Q Series
Standard Hand Held Barcode Reader
Enter/Exit Programming Mode
4
Configuration Using Barcodes
Transmit Labels
in Code 39
Format
This feature enable/disables translation to Code 39 before transmitting label data to a USB-OEM
host. Only the symbology identifier is modified for the translation. The data is not converted to
Code 39 or verified to be valid for Code 39.
Options are:
IBM Standard Format
Send labels in standard IBM format.
Mixed IBM Standard and Code 39 Format
Code 39 Format
Translate the following symbologies to Code 39:
►
USB-OEM: Code128, Code 93, and Codabar
DEFAULT
IBC300(CR)
Transmit Labels in Code 39 Format =
IBM Standard Format
CIBC301(CR)
Transmit Labels in Code 39 Format =
Mixed IBM Standard and Code 39 format
IBC302(CR)
Transmit Labels in Code 39 Format =
All Code 39 Format
DEFAULT
IFO101(CR)
Obey Reader Configuration Host Commands
CIFO102(CR)
Ignore Reader Configuration Host Commands
Interface
Options
This feature provides for an interface-specific control mechanism.