1
Intended use
The BTL7 Micropulse Transducer, together with a machine
controller (e.g. PLC), comprises a position measuring
system. It is intended to be installed into a machine or
system. Flawless function in accordance with the
specifications in the technical data is ensured only when
using original BALLUFF accessories. Use of any other
components will void the warranty.
Opening the transducer or non-approved use are not
permitted and will result in the loss of warranty and liability
claims against the manufacturer.
General safety notes
Installation
and
startup
may only be performed by
trained specialists.
The
operator
is responsible for ensuring that local safety
regulations are observed. In particular, the operator must
take steps to ensure that a defect in the position
measuring system will not result in hazards to persons or
equipment.
If defects and unresolvable faults occur in the transducer, it
should be taken out of service and secured against
unauthorized use.
Downloading further instructions
A complete user's guide can be downloaded from the
Internet at
www.balluff.com/downloads-btl7
or
requested via e-mail from
.
Dimensions and function
The BTL7 transducer contains the waveguide which is
protected by an outer stainless steel tube (rod). A magnet
is moved along the waveguide. This magnet is connected
to the system part whose position is to be determined.
In normal operation LED 1 indicates the operating states of
the transducer:
LED 1
LED 2
Operating state
Green
Off
Normal function
Magnet is within the limits.
Red
Error
No magnet or magnet outside the
limits.
english
EU Directive 2004/108/EC (EMC Directive) and EMC law
Noise immunity: EN 61000-6-1/EN 61000-6-2
Emission: EN 61000-6-3/EN 61000-6-4
File no.
E227256
12.8
Damping zone
Magnet
Null point
End point
B: 30-1 mm
Z: 2"-0.04"
Calibration device
BTL7…-S115
Output signal rising:
Error signal
100 %
0 %
Mounting surface
A: 30-1 mm
Y: 2"-0.04"
Ø D1
G
Mounting surface
Thread size:
B: M18×1.5
Z: 3/4"-16UNF
Thread size:
A: M18×1.5
Y: 3/4"-16UNF
LED 1
LED 2
1)
Unusable area
2)
Not included in scope of
delivery
Version
D1
G
...-A/B/Y/Z-...
10.2 mm
Thread
M4x4/6 deep
...-A8/B8/Y8/Z8-...
8 mm
No thread
1)
1)
2)
1)
Nominal length =
Measuring range
2)
BTL7-A/C/E/G_ _ _ -M _ _ _ _ -A/B/Y/Z(8)-S115
Micropulse Transducer - Rod Style