background image

www.balluff.com

3

english

BSI R11A0-XB-CX...-S75G

Capacitive uniaxial inclination sensor with analog output

No. 890997 EN · G20; subject to modification. Replaces 1301.

Output signal current 4 mA to 20 mA

Inclination sensors BSI R11A0-XB-CXS045-S75G, 

measuring range ±45°

12 mA

4 mA

– 45°

+45°

20 mA

Inclination sensorBSI R11A0-XB-CXP360-S75G,

measuring range 360°

12 mA

4 mA

180°

359,99°

20 mA

Maintenance

The device is maintenance-free in principle. The housing 

can be cleaned as needed using a damp cloth and 

non-corrosive cleaning solution when the device 

is switched off.

Decommissioning

Always uninstall the device in a deenergized state. 

Disposal

Observe the national regulations for disposal.

You can find more information at 

www. balluff.com

 on the product page.

Technical data

General data

Measuring range 

type BSI -...CXS045-...

Type BSI -...CXP360-...

±45°

360°

Measurement axes

1

Direction of rotation

Clockwise and 

counterclockwise

Measuring principle

Capacitive

Protection class

3

Electrical data

Supply voltage U

S

10 to 30 V DC

Output

4 to 20 mA

Output signal

Type BSI -...CXS045-... 

Type BSI -...CXP360-...

4 mA at –45°

20 mA at 45° 

4 mA at 0°

20 mA at 359.99°

Error signal

1 mA

Load max. 

(US–7[V]) / I

max

Resolution max.

±0.01°

Residual ripple

<0.01%

Polarity reversal protected

Yes

Short-circuit protected

Yes

Sampling rate

< 150 ms

Accuracy  

(characteristic deviation)

±0.1% (min. 0.1°)

Temperature drift 

±0.01%/10 K

Lateral angle sensitivity

±0.1° at a lateral tilt of 

up to max. 30°

Current draw

< 31 mA

Settling time

< 1 s

Mechanical data

Housing material

Aluminum

Dimensions

79×28×20 mm

Weight

Approx. 80 g

Connection plug connector

M8, 4-pin

Ambient conditions

Ambient temperature range

–40 to +85 °C

Degree of protection as per  

IEC 60529

IP67

Summary of Contents for BSI R11A0-XB-CX S75G Series

Page 1: ...BSI R11A0 XB CX S75G deutsch Betriebsanleitung english User s guide fran ais Notice d utilisation italiano Manuale d uso espa ol Manual de instrucciones...

Page 2: ...ensor oder eine nichtbestimmungs gem e Verwendung sind nicht zul ssig und f hren zum Verlust von Gew hrleistungs und Haftungsanspr chen gegen ber dem Hersteller Sicherheitshinweise Vor Inbetriebnahme...

Page 3: ...wischen Pin 4 und Pin 3 gemessen Installation Achtung Beachten Sie bei der Montage die Ausrichtung der Neigungsachse Die Neigungssensoren immer im stromlosen Zustand montieren Bei stark vibrierenden V...

Page 4: ...den Sie unter www balluff com auf der Produktseite Technische Daten Allgemeine Daten Messbereich Typ BSI CXS045 Typ BSI CXP360 45 360 Messachsen 1 Drehrichtung Uhrzeigersinn und gegen Uhrzeigersinn Me...

Page 5: ...bles solar panels and excavators Modifications to the sensor or non approved use are not permitted and will result in loss of warranty and void any liability claims against the manufacturer Safety Not...

Page 6: ...n Caution Note the alignment of the rotation axis during installation Always install the inclination sensors in a deenergized state The measurement values can be inexact for equipment that vibrates he...

Page 7: ...e product page Technical data General data Measuring range type BSI CXS045 Type BSI CXP360 45 360 Measurement axes 1 Direction of rotation Clockwise and counterclockwise Measuring principle Capacitive...

Page 8: ...ches de pelles m caniques Les modifications du capteur ou une utilisation non conforme aux prescriptions sont interdits et entra nent la perte des droits de garantie vis vis du fabricant Consignes de...

Page 9: ...et la broche 3 Installation Attention Lors du montage tenez compte de l alignement de l axe d inclinaison Les capteurs d inclinaison doivent toujours tre mont s l tat hors tension Des dispositifs ave...

Page 10: ...de mesure type BSI CXS045 Type BSI CXP360 45 360 Axes de mesure 1 Sens de rotation Sens horaire et sens antihoraire Principe de mesure capacitif Classe de protection 3 Caract ristiques lectriques Tens...

Page 11: ...sensore o un utilizzo non conforme dello stesso non sono consentiti e comporteranno la perdita dei diritti di garanzia e responsabilit nei confronti del costruttore Avvertenze di sicurezza Leggere at...

Page 12: ...allineamento dell asse di inclinazione I sensori di inclinazione devono essere sempre montati in assenza di corrente elettrica Nel caso di dispositivi con forti vibrazioni i valori di misurazione pos...

Page 13: ...balluff com nella pagina del prodotto Dati tecnici Dati generali Campo di misurazione Tipo BSI CXS045 Tipo BSI CXP360 45 360 Assi di misurazione 1 Senso di rotazione Senso orario ed antiorario Princip...

Page 14: ...as modificaciones en el sensor o una utilizaci n indebida no son admisibles e implican la p rdida de todos los derechos de garant a y responsabilidad frente al fabricante Indicaciones de seguridad Ant...

Page 15: ...aje debe tenerse en cuenta la alineaci n del eje de inclinaci n Montar los sensores de inclinaci n siempre en estado sin corriente Los valores de medici n pueden ser inexactos en caso de dispositivos...

Page 16: ...medici n 1 Direcci n de rotaci n Sentido de las agujas del reloj y sentido contrario al de las agujas del reloj Principio de medici n Capacitivo Clase de protecci n 3 Datos el ctricos Tensi n de serv...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...uhausen a d F Phone 49 7158 173 370 Fax 49 7158 173 691 service balluff de US Service Center USA Balluff Inc 8125 Holton Drive Florence KY 41042 Phone 859 727 2200 Toll free 1 800 543 8390 Fax 859 727...