www.balluff.com
17
The specifications are typical values at room temperature.
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
7.1
Accuracy
Position resolution
Analog
Dependent on evaluation
Digital
0.9765625 μm
(1000/1024 µm) per LSB
Repeat accuracy
< 1 μm
Hysteresis
≤ 2 μm
Max. non-linearity of the
sensor head
±2 μm
Max. non-linearity of entire
system (sensor head +
magnetic tape)
±7 μm
Temperature coefficient of
the entire system
10.5 ppm/K
(as with steel)
Movement speed
Max. 7 m/s
7.2
Ambient conditions
1)
Operating temperature
–20 °C to +80 °C
Storage temperature
–30 °C to +85 °C
Shock rating
per EN 60068-2-27
2)
100 g/6 ms
Continuous shock
per EN 60068-2-29
2)
100 g/2 ms
Vibration load
per EN 60068-2-6
2)
12 g, 10 to 2000 Hz
Degree of protection per
IEC 60529 (sensor head
with screwed-on connector)
IP 67
External magnetic fields
– < 30 mT (to avoid
permanent damage)
– < 1 mT (to avoid
influencing the
measurement)
Relative humidity
90% RH, condensation
permitted
7.3
Supply voltage
Supply voltage
3)
5 V ±5%
Current draw
at 5 V supply voltage
< 60 mA + controller current
draw (depending on internal
resistance)
Reverse polarity protection No
Overvoltage protection
No
Dielectric strength
(GND to housing)
500 V DC
7.4
Outputs
SSI
(BML-S1H_-
S
…)
Absolute output
RS 422 differential signal
Bit number
– 16 (BML-S…-M3
A
A-…)
– 18 (BML-S…-M3
C
A-…)
– 20 (BML-S…-M3
F
A-…)
(incl. error and null bits)
Coding
Binary code or gray code
Count direction
Rising or falling
SSI data
Position
SSI clock frequency f
Clk
100 kHz to 4 MHz
BiSS C
(BML-S1H_-
B
…)
Absolute output
RS 422 differential signal
Real-time output
Analog, 1 Vss (sine, cosine
signal)
Output voltage
1 Vss; 1 mm period
Bit number
– 16 (BML-S…-M3
A
A-…)
– 18 (BML-S…-M3
C
A-…)
– 20 (BML-S…-M3
F
A-…)
(4 null bits, 16/18/20
position bits + 1 error bit +
1 warning bit + 6 CRC bits)
Coding
Binary code
Count direction
Rising
BiSS-C data
Position, error bit, warning
bit, CRC
BiSS C clock frequency
2 MHz to 10 MHz
BiSS t
m
time (time until the
interface is ready again)
2 × T
Clk
Additional real-time output
Real-time output
– Analog, incremental
real-time signal
– 1 Vss (sine, cosine signal),
1 mm period
1)
For
: Use in enclosed spaces and up to a height of 2000 m above
sea level.
2)
Individual specifications as per Balluff factory standard
3)
For
: The sensor head must be externally connected via a limited-
energy circuit as defined in UL 61010-1, a low-power source as defined in
UL 60950-1 or a class 2 power supply as defined in UL 1310 or UL 1585.
7
Technical Data
BML-S1H1/2-B/S6 _ C-M3 _ A-D0-KA _ _ , _ -S284
Absolute Magnetically Coded Position Measuring System
english
Summary of Contents for BML-S1H1 Series
Page 2: ...www balluff com...
Page 24: ...english User s Guide BML S1H1 B S6_C M3_A D0 KA_ _ _ S284 BML S1H2 B S6_C M3_A D0 KA_ _ _ S284...
Page 25: ...www balluff com...
Page 48: ...www balluff com...
Page 71: ...www balluff com...
Page 94: ...www balluff com...