BIW1-A/C/E/G310-M_ _ _ _-P1-S115
Micropulse Linear Transducer in Profile Housing
3
english
3
Installation
Fig. 3-1: Dimensional drawing (BIW1...P1-S115 transducer)
Mounting brackets and M4 × 20 cylinder head
screws, DIN 912, max. tightening torque 2 Nm
3.1
Transducer installation
Any orientation is permitted.
Mount the transducer on a level
surface of the machine using the
mounting brackets. Observe the
recommended spacing of the
mounting brackets.
1. Align transducer with sliding
rod.
2. Tighten mounting screws to a
maximum of 2 Nm.
Housing length
A = Nominal 100 mm
Mechanical zero point
B0 = 0 + 2 mm
Electrical zero point
B0 + 5 mm
Electrical stroke = mechanical stroke
B = Nominal 10 mm
Clamp spacing
Nominal length < 300 mm
C = Nominal length - 20 mm
Nominal length 300 mm to < 600 mm
C = Nominal length - 15 mm
Nominal length > 600 mm
C = Nominal length - 10 mm
BIW1-...-M0100-P1-S115
Nominal length 100
A = 200
B = 110
C = 80
BIW1-...-M0360-P1-S115
Nominal length 360
A = 460
B = 370
C = 345
BIW1-...-M0750-P1-S115
Nominal length 750
A = 850
B = 760
C = 740
Table 3-1: Dimensions
Table 3-2: Examples
Available nominal lengths
➥
➥
➥
➥
➥
section 6.2
Ensure that no strong electrical
fields are present in the immedi-
ate vicinity of the transducer.