BIW1-A/C/E/G310-M_ _ _ _-P1-S115
Micropulse Linear Transducer in Profile Housing
7
english
Non-linearity
<± 0.02%
Resolution
A310
5 µm o. 0,15mV
G310
5 µm o. 0,21mV
C/E310
5 µm o. 0,35µA
Hysteresis
1*resolution
Repeatability
2*resolution
Supply voltage sensitivity
U
a
/U
b
< 0.1 mV/V
Warm-up phase
< 5 min
Temperature coefficient < 20ppm/K
Shock loading
100 g/6 ms
per EN 60068-2-27
1
Continuous shock 100 g/2 ms
per EN 60068-2-29
1
Vibration 12 g, 10 to 2000 Hz
per EN 60068-2-6
1
1
Individual specifications as per
Balluff factory standard
Enclosure rating
per IEC 60529
IP54
7.1
Supply voltage
(external from Limited
Energy Circuit as defined in
IEC 61010 or Low Power Source
IEC 60950 or Class 2 power supply
as defined in NEC or CEC)
Supply Voltage U
b
24 V ±6 V
Current draw
< 80 mA
typical
Inrush
< 3 A
Polarity reversal
protection
built-in
Overvoltage protection
Transzorb diodes
Electric strength
500 V DC
7
Technical Data
The following are typical values at DC 24 V and room temperature. Fully operational after power-up, with full
accuracy after warm-up.
7.2
Outputs
Output voltage U
a
:
BIW1-A310-...
0...10 V
BIW1-G310-...
-10...+10 V
Output noise
< 5 mV
Output current
< 6 mA
Output current I
a
:
BIW1-C310-...
0...20 mA
BIW1-E310-... 4...20 mA
Output noise
< 10 µA
Load resistance
< 500 Ohm
Sampling rate typ.
32 kHz
(30...33 kHz)
Short circuit protection
built-in
Cable length
A/G
< 25 m
C/E
< 100 m
No. 837 922 - 726 E • 03.111450 • Edition 1004; specifications subject to changes. • Replaces edition 0908.
The following patents have been
granted in connection with this
product:
US 2003/0206007 A1;
DE 102 19 678 C1
UL approval
File no.
E227256
Emission tests:
RF Emission
EN 55016-2-3 (industrial and
residential area)
Noise immunity tests:
Static electricity (ESD)
EN 61000-4-2
Severity level 3
Electromagnetic fields (RFI)
EN 61000-4-3
Severity level 3
Fast transients (Burst)
EN 61000-4-4
Severity level 3
Surge
EN 61000-4-5
Severity level 2
Line-induced noise induced by
high-frequency fields
EN 61000-4-6
Severity level 3
Magnetic fields
EN 61000-4-8
Severity level 4
The CE Mark verifies
that our products meet
the requirements of
EU Directive
2004/108/EC (EMC Directive)
and the EMC Law. Testing in our
EMC Laboratory, which is accred-
ited by DATech for Testing Elec-
tromagnetic Compatibility, has
confirmed that Balluff products
meet the EMC requirements of
the following Generic Standards:
EN 61000-6-1 (noise immunity)
EN 61000-6-2 (noise immunity)
EN 61000-6-3 (emission)
EN 61000-6-4 (emission)
and the following product standard:
EN 61326-2-3
7.3
Dimensions, weights,
ambient conditions
Nominal length
< 775 mm
Dimensions
➥
➥
➥
➥
➥
page 3
Weight
approx. 1.0 kg/m
Housing
Aluminium
Housing attachment
Mounting brackets and screws
max. tightening torque
2 Nm
Operating temp. –20 °C to +85 °C
Storage temp. –40 °C to +100 °C
Operating force on rod
Horizontal
< 10 N
Vertical
< 10 N