BIW1-A/C/E/G310-M_ _ _ _-P1-S115
Micropulse Linear Transducer in Profile Housing
english
6
5
Startup
5.1
Check connections
Although the connections are polar-
ity reversal protected, components
can be damaged by improper con-
nections and overvoltage. Before
you apply power, check the connec-
tions carefully.
5.2
Turning on the system
Note that the system may execute
uncontrolled movements when first
turned on or when the transducer is
part of a closed-loop system whose
parameters have not yet been set.
Therefore make sure that no haz-
ards could result from these
situations.
5.3
Check output values
After replacing or repairing a trans-
ducer, it is advisable to verify the
values for the start and end position
of the sliding rod in manual mode.
5.4
Check functionality
The functionality of the transducer
system and all its associated com-
ponents should be regularly
checked and recorded.
5.5
Fault conditions
When there is evidence that the
transducer system is not operating
properly, it should be taken out of
service and guarded against unau-
thorized use.
Supply voltage
3 = DC 24 V potential isolated
Electr. connection: with connector S115
BIW1-A310-M0450-P1-S115
Profile form factor
Nom. length (4digits): M = metric in mm
Interface: A = 0...+10 V
C = 0...20 mA
E = 4...20 mA
G = -10...+10 V
Micropulse
Linear T
ransducer
6
Versions (indicated on part label)
Ordering
code:
BIW_ _ _ _
Type:
6.1
Included in shipment
Transducer with condensed guide
and 2 mounting brackets.
6.2
Available lengths
The following nominal stroke
lengths are available:
0075, 0100, 0130, 0150, 0175,
0225, 260, 0300, 0360, 0375,
0400, 0450, 0500, 0600, 0650,
0750
Other stroke lengths on request.
6.3
Accessories
(optional)
Connectors
➥
Fig. 4-3
straight:
BKS-S115-PU-_ _
right angle:
BKS-S116-PU-_ _