9th example
Read the EPCs of multiple data carriers in front of
the antenna
With a maximum number of 5, EPC size of 12 bytes
configured, 3 data carriers identified
Command from controller
BIS U-6026 reaction
1.
Edit output buffer
(observe sequence):
2.
Edit input buffer
(observe sequence):
01
hex
Command designator 47
hex
00
hex
/0F
hex
Set AA bit
02
hex
Type EPC 00
hex
01
hex
Enter number of data carriers 03
hex
03
hex
Max. number 05
hex
02
hex
Enter number of bytes per EPC 0C
hex
00
hex
/0F
hex
Set AV bit
03
hex
…0E
hex
Enter first EPC 12 bytes
00
hex
/0F
hex
Set AE bit
3a. Process input buffer:
4.
Process input buffer:
01
hex
Note number of data carriers
01…0C
hex
Enter second EPC 12 bytes
02
hex
Save number of bytes
0D
hex
/0E
hex
Enter third EPC 2 bytes
03
hex
/0E
hex
Copy first EPC 12 bytes
00
hex
/0F
hex
Invert TO bit
3b. Process output buffer:
00
hex
/0F
hex
Invert TI bit
5a. Process input buffer:
6.
Process input buffer:
01
hex
…0C
hex
Copy second EPC 12 bytes
01
hex
…0A
hex
Enter third EPC 10 bytes
0D
hex
/0E
hex
Copy third EPC 2 bytes
00
hex
/0F
hex
Invert TO bit
5b. Process output buffer:
00
hex
/0F
hex
Invert TI bit
7a. Process input buffer:
8.
Process input buffer:
01
hex
/0A
hex
Copy third EPC 10 bytes
00
hex
/0F
hex
Reset AA and AE bits
7b. Process output buffer:
00
hex
/0F
hex
Reset AV bit
8
Device function (continued)
BIS U-6026-034-1_4-06-ST35
Processor unit
Summary of Contents for BIS U-6026-034-104-06-ST35
Page 2: ...www balluff com...
Page 4: ...www balluff com...
Page 50: ...www balluff com...
Page 95: ...BIS U 6026 034 104 06 ST35 BIS U 6026 034 114 06 ST35 BIS U 6026 034 124 06 ST35...
Page 96: ...www balluff com...
Page 113: ...www balluff com 19 BIS BIS 4 RS232 1 2 2 0 5 Tag 128 Tag Tag 5 7 BIS U 6026 034 1_4 06 ST35...
Page 136: ...42 8 KA HD 1 1 3 2 2 4 1 00hex 0Fhex KA KA 8 BIS U 6026 034 1_4 06 ST35...