Setting the processor unit parameters (continued)
Read/write
User data start address
Start address of the USER data for automatic reading
during data carrier searches and if USER data is used as
an address during reading or writing.
Factory setting:
0 bytes
User data length
Length of the USER data for automatic reading during data
carrier searches and if USER data is used as an address
during reading or writing. The value range is 1 to 16.
Factory setting:
16 Byte
TID length
Length of the TID data with value range from 2 to 12.
Factory setting:
12 Byte
If data carriers have a length other than the TID
set here, it is possible that they cannot be read
from or written to.
EPC length
Length of the EPC format on the data carriers. This
parameter determines the maximum length of the EPC
data to be processed and the output format for the
command
Read multiple data carriers (EPC)
.
Factory setting:
96 Bit
If the actual EPC length of the data carriers is
not equivalent to 96 bits, set the value to
496 bits. Otherwise the read and write
commands cannot be run without errors.
BIS U-6026-034-1_4-06-ST35
Processor unit
Summary of Contents for BIS U-6026-034-104-06-ST35
Page 2: ...www balluff com...
Page 4: ...www balluff com...
Page 50: ...www balluff com...
Page 95: ...BIS U 6026 034 104 06 ST35 BIS U 6026 034 114 06 ST35 BIS U 6026 034 124 06 ST35...
Page 96: ...www balluff com...
Page 113: ...www balluff com 19 BIS BIS 4 RS232 1 2 2 0 5 Tag 128 Tag Tag 5 7 BIS U 6026 034 1_4 06 ST35...
Page 136: ...42 8 KA HD 1 1 3 2 2 4 1 00hex 0Fhex KA KA 8 BIS U 6026 034 1_4 06 ST35...