![Balluff BIS Series Manual Download Page 38](http://html1.mh-extra.com/html/balluff/bis-series/bis-series_manual_3613914038.webp)
13
13
english
BIS M-81_
Start-up
Turning on the
Handy Programmer
(cont.)
If the voltage has dropped below a certain nominal capac-
ity, a warning message is issued. The unit can still be oper-
ated for a short time in spite of this warning. The battery
should however be recharged as soon as possible
(see 53).
After pressing the
«
key the unit indicates its battery state in the following display.
Following a passed battery test this display will appear automatically.
!!!!!!!!!!!!!!!!!!
Battery low!
!!!!!!!!!!!!!!!!!!
Battery warning message
---
Main menu
---
1 READ
4 File
2 WRITE
5 Config
3 Edit
6 More
Main menu 1
M-81_854610_E_0703.p65
14
english
14
BIS M-81_
Configuration
If you do not wish to use the factory setting, start by con-
figuring the Handy Programmer.
Menu item 5 in Main Menu 1 takes you to Configuration
Menu 1:
The address ranges for reading and writing of data carriers and for the jump-to address for
editing can be preset.
The selection number for the respective mode as well as the
desired values must be entered and confirmed by pressing
the
«
key. Values you want to copy can be confirmed di-
rectly by pressing
«
. In this way you can proceed through
the displayed menus one after the other.
Input mode READ:
Start address / End address or
Start address / Number of bytes for reading
Configuring
addresses
51
Configuration 1
5
READ range
Input mode: READ
--------------------
0 -> Start/End addr.
1 -> Start/Number 0
Select input mode for reading
READ range
--------------------
at byte no. :
to
0
byte no. : 255
Input menu 0 for mode
Start/End address for reading
READ range
--------------------
at byte no. :
no. of b
0
ytes: 0256
Input menu 1 for mode
for reading
Start
address/No. of bytes