39
39
E
Example No. 6
For configuring with
double bit header
and 8-byte buffer
size!
Write 16 bytes starting at data carrier address 20
(data carrier type with 32 byte block size)
:
Host:
1.)
Process subaddresses of the output buffer in the
order shown:
BIS C-60_2 Identification System:
2.)
Process subaddresses of the input buffer in the
order shown:
3.)
Process subaddresses of the output buffer:
4.)
Process subaddresses of the output buffer:
9.)
Process subaddresses of the output buffer:
10.)
Process subaddresses of the input buffer:
5.)
Process subaddresses of the output buffer:
6.)
Process subaddresses of the output buffer:
7.)
Process subaddresses of the output buffer:
8.)
Process subaddresses of the output buffer:
01
Hex
Command designator 02
Hex
02
Hex
/03
Hex
Start address 14
Hex
/ 00
Hex
04
Hex
/05
Hex
No. of bytes 10
Hex
/ 00
Hex
00
Hex
/07
Hex
CT-Bit to 0 (32 Byte block size),
set AV-Bit
00
Hex
/07
Hex
Set AA-Bit, invert TO-Bit
01...06
Hex
Enter the first 6 data bytes
00
Hex
/07
Hex
Invert TI-Bit
01...06
Hex
Copy the first 6 data bytes
Process subaddress of the input buffer:
00
Hex
/07
Hex
Invert TO-Bit
01...06
Hex
Enter the second 6 data bytes
00
Hex
/07
Hex
Invert TI-Bit
01...06
Hex
Copy the second 6 data bytes
Process subaddress of the input buffer:
00
Hex
/07
Hex
Invert TO-Bit
01...04
Hex
Enter the remaining 4 data bytes
00
Hex
/07
Hex
Invert TI-Bit
01...04
Hex
Copy the remaining 4 data bytes
Process subaddress of the input buffer:
00
Hex
/07
Hex
Set AE-Bit
00
Hex
/07
Hex
Reset AV-Bit
00
Hex
/07
Hex
Reset AA-Bit and AE-Bit
Function Description
Examples for protocol sequence
C60_2-028_823024_0401-e.p65
40
40
E
Example No. 7
Store Mixed Data
Access program
For configuring with
double bit header
and 8-byte buffer
size!
Storing a program for reading out 3 data records:
1st data record
Start address
5
Number of bytes
7
2nd data record
Start address
75
Number of bytes
3
3rd data record
Start address
312
Number of bytes
17
Total number of bytes exchanged in the operation:
27 bytes
All 104 bytes are written for the programming.
Host:
1.)
Process subaddresses of the output buffer in the
order shown:
Host:
2.)
Process subaddresses of the input buffer:
01
Hex
Command designator 06
Hex
02
Hex
Program number 01
Hex
00
Hex
/07
Hex
CT-Bit to 0 or 1
(depending on block size),
set AV-Bit
00
Hex
/07
Hex
Set AA-Bit, invert TO-Bit
3.)
Process subaddresses of the output buffer:
4.)
Process subaddresses of the input buffer:
01
Hex
1st start address
(Low Byte) 05
Hex
02
Hex
(High Byte) 00
Hex
03
Hex
1st number of bytes (Low Byte) 07
Hex
04
Hex
(High Byte) 00
Hex
05
Hex
2nd start address
(Low Byte) 4B
Hex
06
Hex
(High Byte) 00
Hex
00
Hex
/07
Hex
Invert TI-Bit
00
Hex
/07
Hex
Invert TO-Bit
Continued on next .
Function Description
Examples for protocol sequence
All manuals and user guides at all-guides.com