73
73
E
BIS C-6022
Technical Data
Function displays
The CE-Mark is your assurance that our products are in conformance with the
EC-Guideline
89/336/EEC (EMC-Guideline)
and the EMC Law. Testing in our EMC Laboratory, which is accredited by the DATech for
Testing of Electromagnetic Compatibility, has confirmed that Balluff products meet the
EMC requirements of the Generic Standard
EN 61000-6-4 (Emission) and EN 61000-6-2 (Noise Immunity).
Digital input +IN
Optocoupler isolated
Control voltage active
4 V to 40 V
Control voltage inactive
1.5 V to –40 V
Input current at 24 V
11 mA
Delay time, typ.
5 ms
PROFIBUS-DP, Connector X2, X3
serial interface for PROFIBUS stations
Head 1, Head 2, Read/Write Head
via 2 x connectors for all
read/write heads BIS C-3_ _
with 4-pin connector (female),
excluding
BIS C-350 and BIS C-352
Service interface X4
RS 232
BIS operating messages:
Ready / Bus active
LED red / green
CT1 Present / operating
LED green / yellow
CT2 Present / operating
LED green / yellow
Electrical
Connections
(continued)
C60_2-028_823024_0401-e.p65
74
74
E
BIS C-6022-028-050-03-ST_ _
Balluff Identification System
Type C Read/Write System
Hardware Type
6022 = metal housing, PROFIBUS-DP
Software Type
028 = PROFIBUS-DP with memory optimization
Version
050 = with two connections for external read/write heads BIS C-3_ _
(except BIS C-350 and -352)
Interface
03 = bus versions
User Connection
ST10 = Connector version X1, X2, X3, X4 (male: 1× 5-pin, 1× 4-pin, female: 2× 12-pin)
ST14 = Connector version X1, X2, X3, X4 (male: 2× 5-pin, 1× 4-pin, female: 1× 5-pin)
Type
Ordering code for ST10
Ordering code for ST14
Mating connector
for X1
BKS-S 79-00
BKS-S 79-00
for X2
BKS-S 86-00
BKS-S103-00
for X3
BKS-S 86-00
BKS-S105-00
for X4
BKS-S 10-3
BKS-S 10-3
Protective cap
for Head_, X4
BES 12-SM-2
BES 12-SM-2
Protective cap
115 475 for X2
BKS 12-CS-01 for X3
Termination
BKS-S105-R01 for X3
Ordering code
BIS C-6022
Ordering Information
Accessory
(optional,
not included)
All manuals and user guides at all-guides.com