61
61
E
Digital Input (+IN, –IN)
Terminal block, Optocoupler isolated
Control voltage active
4 V to 40 V
Control voltage inactive
1.5 V to –40 V
Input current at 24 V
11 mA
Delay time, typ.
5 ms
Control outputs CT Present 1 and 2
Optocoupler isolated
Output circuit PNP (current sourcing)
Operating voltage V
SO
(external) for output
DC 24 V ± 20 %
Ripple
≤
10 %
Output current
max. 20 mA
Voltage drop at 20 mA
approx. 2.5 V
Output resistance R
A
10 k
Ω
to –V
SO
Service interface
RS 232
Read/Write Head
integrated, BIS C-65_ and following *);
option for mounted adapter BIS C-650 *)
2 x connectors 4-pin (male)
for all read/write heads BIS C-3_ _
with 4-pin connector (female),
except
BIS C-350 and BIS C-352
option for mounted adapter BIS C-670 *)
1 x connector 8-pin (male)
for one of the read/write heads
BIS C-350 or BIS C-352
BIS operating messages:
Ready / Bus active
LED red / green
CT1 Present / operating
LED green / yellow
CT2 Present / operating
LED green / yellow
Electrical
Connections
(continued)
BIS C-6002
Technical Data
Function Displays
*) rotatable by 90 degrees
with KL2 only:
C60_2-028_823024_0401-e.p65
62
62
E
The CE-Mark is your assurance that our products are in conformance with the
EC-Guideline
89/336/EEC (EMC-Guideline)
and the EMC Law. Testing in our EMC Laboratory, which is accredited by the DATech for
Testing of Electromagnetic Compatibility, has confirmed that Balluff products meet the
EMC requirements of the Generic Standard
EN 61000-6-4 (Emission) and EN 61000-6-2 (Noise Immunity).
BIS C-6002
Technical Data
All manuals and user guides at all-guides.com
all-guides.com