background image

Instruction manual BES M12MG2-GNX40F-BT02-EXB

Instruction manual BES M12MG2-GNX40F-BT02-EXB

BA-S36055-GB-2019-03

BA-S36055-GB-2019-03

Page 1

Page 4

0102

Inductive Sensor

Order Code: BES05NN

BES M12MG2-GNX40F-BT02-EXB

Instruction manual

Balluff GmbH

Schurwaldstr. 9

D-73765 Neuhausen a.d.F.

Tel.  +49 7158 173-0

Fax. +49 7158 5010

www.balluff.com

[email protected]

Intended use

The inductive proximity switch is for use as contactless wearout-free limit switch in

industrial control systems.

The inductive proximity switch may only be connected to electronic evaluation devices that 

have a valid EC type examination certificate for hazardous areas with potentially explosive 

gas and dust atmosphere and do not exceed the electrical limits of the inductive proximity 

switch. 

It can be mounted inside gas-hazardous areas that require equipment of category 1G

 

(zone 0) or dust-hazardous areas that require equipment of category 1D (zone 20).

If there are additional regulations for the particular design regarding the installation, they must be observed as well.

Safety instructions

•  Only professionals with sufficient knowledge are allowed to install and operate the device.

•   Prior to installation disconnect the system from power supply.

•   Comply with the provisions of the instruction manual.

•  Comply with the national regulations and installation provisions (e.g. EN 60079-14).

•   Absolutely abide by the specific conditions.

Installation and operation

•  Make sure that the device is used only in the area of application corresponding to its Ex marking.

•  Do not modify the device (e.g. painting).

•  Make sure that the housing of the proximity switch has electrical contact to a grounded metal structure.

•  Install cables according to the applicable regulations and protect them from damage.

•  The device complies with the EMC requirements for proximity switches according to

  EN 60947-5-2:2007+A1:2012.

•  Cables longer than 30 m can require additional EMC measures.

•  Datasheet, EU type examination certificate and MTTF values are available on request.

Maintenance, repairs and trouble-shooting

  Do not modify or repair the device – its approval will expire. Contact the manufacturer for any problems.

•  Prevent dust from covering the device, i.e by regulary cleaning with a damp cloth.

Specific conditions

•  Protect the device from UV light.

•  Markings that are not on the device will be found in the instruction manual.

The following standards have been applied:

EN 60079-0:2012 + A11:2013

EN 60079-11:2012
EN 60947-5-6:2000
EN 50581:2012

IEC 60079-0:Edition 6.0 2011-06
IEC 60079-11:Edition 6.0 2011-07

Summary of Contents for BES M12MG2-GNX40F-BT02-EXB

Page 1: ...deutsch Betriebsanleitung english User s guide fran ais Notice d utilisation espa ol Manual de instrucciones portugu s Manual de instru es BES M12MG2 GNX40F BT02 EXB...

Page 2: ...IIC T6 Ga Staub Ex Ex ia lllC T65 C Da Baumusterpr fbescheinigung EPS 18 ATEX 1 031 X Benannte Stelle f r die berwachung des Qualit tssicherungssystems Physikalisch Technische Bundesanstalt PTB NB 01...

Page 3: ...umentation technique est archiv e par le fabricant IT La documentazione tecnica viene archiviata presso il costruttore ES El fabricante se encarga de archivar la documentaci n t cnica NL De technische...

Page 4: ...bsanleitung einhalten Geltende nationale Vorschriften und Errichterbestimmungen z B EN 60079 14 einhalten Die besonderen Bedingungen unbedingt beachten Installation und Inbetriebnahme Anhand der Ex Ke...

Page 5: ...istung Pi 50 mW wirksame innere Kapazit t Ci 66 2 nF wirksame innere Induktivit t Li 1 2 mH Elektrostatisch aufladbare Kunststoffoberfl chen Betrachtung nach Gruppe II Gas 121 mm Betrachtung nach Grup...

Page 6: ...onsgef hrdeter Bereich non hazardous area 52 44 4 M12x1 17 10 betriebsm ig geerdeter metallischer Montagerahmen grounded metal frame Bauform type max Drehmoment max torque M12x1 M18x1 M30x1 5 10 Nm 25...

Page 7: ...bH Schurwaldstr 9 D 73765 Neuhausen a d F Tel 49 7158 173 0 Fax 49 7158 5010 www balluff com balluff balluff de Folgende Normen wurden angewandt EN 60079 0 2012 A11 2013 EN 60079 11 2012 EN 60947 5 6...

Page 8: ...ion disconnect the system from power supply Comply with the provisions of the instruction manual Comply with the national regulations and installation provisions e g EN 60079 14 Absolutely abide by th...

Page 9: ...Pi 50 mW Effective internal capacity Ci 66 2 nF Effective internal inductivity Li 1 2 mH Electrostatic chargeable plastic housing With reference to group II gas 121 mm With reference to group III dust...

Page 10: ...losionsgef hrdeter Bereich non hazardous area 52 44 4 M12x1 17 10 betriebsm ig geerdeter metallischer Montagerahmen grounded metal frame Bauform type max Drehmoment max torque M12x1 M18x1 M30x1 5 10 N...

Page 11: ...churwaldstr 9 D 73765 Neuhausen a d F Tel 49 7158 173 0 Fax 49 7158 5010 www balluff com balluff balluff de The following standards have been applied EN 60079 0 2012 A11 2013 EN 60079 11 2012 EN 60947...

Page 12: ...les prescriptions et les dispositions d installation nationales applicables par exemple la norme EN 60079 14 Il convient imp rativement de tenir compte des conditions particuli res Installation et mis...

Page 13: ...mH Surfaces en mati res synth tiques susceptibles d tre charg es d lectricit statique Consid ration conform ment au groupe II gaz 121 mm Consid ration conform ment au groupe III poussi re 475 mm Mat...

Page 14: ...2x1 M18x1 M30x1 5 10 Nm 25 Nm 40 Nm Dimensions Contenu de la livraison transport et limination V rifiez que l emballage et le contenu ne soient pas endommag s V rifiez que la livraison soit compl te R...

Page 15: ...churwaldstr 9 D 73765 Neuhausen a d F T l 49 7158 173 0 Fax 49 7158 5010 www balluff com balluff balluff de Les normes suivantes ont t appliqu es EN 60079 0 2012 A11 2013 EN 60079 11 2012 EN 60947 5 6...

Page 16: ...las normativas nacionales y las normas de instalaci n vigentes p ej EN 60079 14 Observe las condiciones especiales sin excepci n Instalaci n y puesta en funcionamiento Compruebe si el equipo es apto p...

Page 17: ...i n Pi 50 mW capacidad interna efectiva Ci 66 2 nF inductividad interna efectiva Li 1 2 mH Superficies pl sticas electrost ticas de carga Consideraci n por grupo II gas 121 mm Consideraci n por grupo...

Page 18: ...max Drehmoment max torque M12x1 M18x1 M30x1 5 10 Nm 25 Nm 40 Nm Dimensiones Volumen de suministro transporte y eliminaci n Compruebe que el embalaje y el contenido no est n da ados Compruebe que la e...

Page 19: ...GmbH Schurwaldstr 9 D 73765 Neuhausen a d F Tel 49 7158 173 0 Fax 49 7158 5010 www balluff com balluff balluff de Se han aplicado las siguientes normas EN 60079 0 2012 A11 2013 EN 60079 11 2012 EN 609...

Page 20: ...fornecidas no manual de instru es Cumprir as disposi es nacionais e os regulamentos de constru o vigentes tais como EN 60079 14 Respeitar imprescindivelmente as condi es especiais Instala o e entrada...

Page 21: ...5 zona 0 20 C Ta 60 C Faixa de temperatura em T4 zona 0 20 C Ta 60 C Faixa de temperatura em T3 zona 0 20 C Ta 60 C Faixa de temperatura em T6 zona 1 60 C Ta 60 C Faixa de temperatura em T5 zona 1 60...

Page 22: ...x Drehmoment max torque M12x1 M18x1 M30x1 5 10 Nm 25 Nm 40 Nm Medidas Material fornecido transporte e elimina o Verifique se a embalagem e o conte do apresentam danos Verifique se o material fornecido...

Page 23: ...mbH Schurwaldstr 9 D 73765 Neuhausen a d F Tel 49 7158 173 0 Fax 49 7158 5010 www balluff com balluff balluff de Foram aplicadas as seguintes normas EN 60079 0 2012 A11 2013 EN 60079 11 2012 EN 60947...

Page 24: ...BES M12MG2 GNX40F BT02 EXB BA S36055 CHN 2019 03 1 0102 BES05NN BES M12MG2 GNX40F BT02 EXB EC 1G 0 1D 20 EN 60079 14 EN 60947 5 2 2007 A1 2012 30m MTTF...

Page 25: ...60 C T5 0 20 C Ta 60 C T4 0 20 C Ta 60 C T3 0 20 C Ta 60 C T6 1 60 C Ta 60 C T5 1 60 C Ta 60 C T4 1 60 C Ta 60 C T3 1 60 C Ta 60 C 20 60 C Ta 60 C 20 65 C 21 60 C Ta 60 C 21 65 C Ui 12 6 V Ii 15 9 mA...

Page 26: ...ous area BN BU eigensicherer zertf Sensor nach intrinsically safe sensor accord to NAMUR DIN EN 60947 5 6 IEC 60947 5 6 nichtexplosionsgef hrdeter Bereich non hazardous area 52 44 4 M12x1 17 10 betrie...

Page 27: ...9 03 4 Balluff GmbH Schurwaldstr 9 D 73765 Neuhausen a d F 49 7158 173 0 49 7158 5010 www balluff com balluff balluff de EN 60079 0 2012 A11 2013 EN 60079 11 2012 EN 60947 5 6 2000 EN 50581 2012 IEC 6...

Page 28: ...BES M12MG2 GNX40F BT02 EXB BA S36055 RU 2019 03 1 0102 BES05NN BES M12MG2 GNX40F BT02 EXB 1G 0 1D 20 EN 60079 14 EX EN 60947 5 2 2007 A1 2012 30...

Page 29: ...Da T6 0 20 C Ta 60 C T5 0 20 C Ta 60 C T4 0 20 C Ta 60 C T3 0 20 C Ta 60 C T6 1 60 C Ta 60 C T5 1 60 C Ta 60 C T4 1 60 C Ta 60 C T3 1 60 C Ta 60 C 20 60 C Ta 60 C 20 65 C 21 60 C Ta 60 C 21 65 C Ui 1...

Page 30: ...ous area BN BU eigensicherer zertf Sensor nach intrinsically safe sensor accord to NAMUR DIN EN 60947 5 6 IEC 60947 5 6 nichtexplosionsgef hrdeter Bereich non hazardous area 52 44 4 M12x1 17 10 betrie...

Page 31: ...9 03 4 Balluff GmbH Schurwaldstr 9 D 73765 Neuhausen a d F 49 7158 173 0 49 7158 5010 www balluff com balluff balluff de EN 60079 0 2012 A11 2013 EN 60079 11 2012 EN 60947 5 6 2000 EN 50581 2012 IEC 6...

Page 32: ...e KY 41042 Phone 859 727 2200 Toll free 1 800 543 8390 Fax 859 727 4823 technicalsupport balluff com CN Service Center China Balluff Shanghai trading Co ltd Room 1006 Pujian Rd 145 Shanghai 200127 P R...

Reviews: