43
43
E
Wiring diagram
for BIS C-602-...-KL2
processors with
BIS C-650 adapter
Terminal location and
designation
Terminal
block
Connection for read/write head 1
Connection for read/write head 2
PROFIBUS-DP
Supply voltage and digital input
Protection
ground PE
BIS C-602-...-KL2
Wiring Diagrams
Terminal block connections
n.c. = do not connect!
The ground connector should be connected to
earth directly or through a RC combination
depending on the system (potential counter-
poise).
When connecting the bus leads, make sure that
the shield has proper connection to the PG hous-
ing. Please note the assembling instructions on
40.
19
18
17
16...14
13
12
11...8
+ VS - VS
n.c.
+IN
-IN
n.c.
POWER
INPUT
7
6
5
4
3
2
1
DGND
A
B
VP
DGND
A
B
PROFIBUS-DP
C6_2-019_641365_0506-e.p65
44
44
E
Terminal block connections
n.c. = do not connect!
The ground connector should be connected to
earth directly or through a RC combination
depending on the system (potential counter-
poise).
When connecting the bus leads, make sure that
the shield has proper connection to the PG hous-
ing. Please note the assembling instructions on
40.
Terminal for read/write head (8 pin)
Terminal location and
designation
Terminal
block
PROFIBUS-DP
Supply voltage and digital input
Protection
ground PE
BIS C-602-...-KL2
Wiring Diagrams
Wiring diagram
for BIS C-602-...-KL2
processors with
BIS C-670 adapter
19
18
17
16...14
13
12
11...8
+ VS - VS
n.c.
+IN
-IN
n.c.
POWER
INPUT
7
6
5
4
3
2
1
DGND
A
B
VP
DGND
A
B
PROFIBUS-DP