Remote bus cable
for PROFIBUS-DP
To insert BIS C-602-...-ST11 processor into the serial PROFIBUS-DP, there are the terminal X2
for the PROFIBUS input and the terminal X3 for the PROFIBUS output.
...
1
2
3
4
1
2
3
4
A
B
VP
DGND
A
B
VP
DGND
A
B
A
B
In case the processor is the last bus module in the chain, then only the incoming cable is
connected to X2.
The last bus module must terminate the bus with a resistor. In the case of the BIS C-602, this
can be realized in two different ways:
1.
Inside the unit
by closing switch S2
(factory set to open)
Note:
The PROFIBUS output
must be closed off with a cap
in order to maintain the enclosure
rating.
2.
Outside the unit
in the mating male connector for X3. Bring out the signals VP (Pin 1)
and DGND (Pin 3) to tie the external termination resistors to plus.
Note:
S2 must be
open!
BIS C-602-...-ST11
Wiring Diagrams
X4/1...X4/3
Termination resistor
closed
active
open
passive
Bus station BIS C-602-...-ST11
Bus station
Bus station
5-pin female
X3, output
5-pin male
X2, input
Output
Input
Connect shield
to connector
housing
Connect shield
to connector
housing
green
red
green
red
C6_2-019_641365_0506-e.p65
46
46
E
Wiring diagram for
BIS C-602-...-ST11
processor with
adapter BIS C-657
PROFIBUS-DP
Supply
voltage,
digital input
Protection
ground
BIS C-602-...-ST11
Wiring Diagrams
1
2
3
5
4
X1
, Supply voltage, digital input
X2
, PROFIBUS-
input (male)
1
2
3
5
4
n.c. = do not
connect
X3
, PROFIBUS-
output (female)
2
1
4
5
3
Pin
Function
1
VP
2
A
3
DGND
4
B
5
n.c.
Pin
Function
1
+Vs
2
IN
3
Vs
4
+IN
5
n.c.
Connection for
read/write head
The ground connector should be connected to earth directly or through a RC combination
depending on the system (potential counterpoise).
When connecting the bus leads, make sure that the shield has proper connection to connector
housing.
Terminal location
and designation