8. TROUBLESHOOTING
36
In case of occurrence of a trouble during operation, the system stops itself, and then the
trouble description is displayed. If you want the trouble description to be reappeared,
press the “Sensor Switch” button and set the remote controller to the “Self Temperature
Control” and then to the “Remote Temperature Control”.
a. Model KFR-28GW/BPx2/2801 GW/BPx2
The trouble indicator and run indicator share a LCD (the symbol means flashing and
means constant light).
Trouble Display
Code
Run Standby Timer
High-
efficiency
Description of Trouble
Cause of Trouble
1
Room temperature sensor
abnormal
Thermistor short-circuited or
open circuited
2
Heat exchanger
temperature sensor
abnormal
Thermistor short-circuited or
open circuited
3
Heat exchanger frozen
4
Heat exchanger overheated
5
Communication in trouble
8
Indoor fan in trouble
1
Outdoor ambient
temperature sensor
abnormal
Thermistor short-circuited or
open circuited
2
Outdoor heat exchanger
temperature sensor
abnormal
Thermistor short-circuited or
open circuited
3
Compressor overheated
Thermistor short-circuited or
open circuited, or compressor
overheated
4
Outdoor capillary tube A
temperature sensor in
trouble
Thermistor short-circuited or
open circuited
5
Outdoor capillary tube B
temperature sensor in
trouble
Thermistor short-circuited or
open circuited
6
Overcurrent trouble
Too large electric current in the
outdoor unit
7
No load
Compressor not connected or the
module damaged
8
Supply voltage abnormal
Too high or too low supply
voltage
9
Instantaneous interruption
of power
Summary of Contents for KFR-2501G/Y2BPE
Page 14: ...5 REFRIGERANT SYSTEM DIAGRAM 3 OUTLINES AND DIMENSIONS KFR 28G BPEX2 ...
Page 15: ...5 REFRIGERANT SYSTEM DIAGRAM 3 OUTLINES AND DIMENSIONS 14 KFR 2601G BPE 2 ...
Page 23: ...5 REFRIGERANT SYSTEM DIAGRAM 22 ...
Page 24: ...5 REFRIGERANT SYSTEM DIAGRAM 23 ...
Page 54: ...KFR 28G BPE 2 11 DISASSEMBLY INSTRUCTIONS ...
Page 63: ...12 PARTS LIST KFR 2601G BPE 2 KFR 2501G BPE 62 ...
Page 64: ...12 PARTS LIST KFR 2801G BPE 2 63 ...