11. DISASSEMBLY INSTRUCTIONS
OPERATING PROCEDURE
PHOTOS
4. Remove the electrical control Box ass'y
1) Remove all the terminals of the electrical
control box ass'y.
2) Take out the screws and remove the electrical
control box.
Electrical control box ass'y
Screws
Compressor
wire
Discharge tube
Back guard
Compressor
Liquid tank
Terminal cover
Noise dfending cover
Back guard
61
Screws
Electrical control box ass'y
5. Remove the compressor
1) Remove the back guard.
2) Remove the compressor terminal cover and
the compressor wire.
3) Disconnect the compressor and the discharge
tube, liquid tank, and the suction tube.
5) Remove the noise defending cover.
6) Take out the nut of the compressor and
remove the compressor.
Suction tube
Summary of Contents for KFR-2501G/Y2BPE