BVRD Series Microphones
Installation Instructions
BVRD Series Microphones issue 5
17
4.5 F
AULT
R
EPORTING
4.5.1 Common / System Faults
If a fault is reported on the system the common “SYSTEM
FAULT” Indicator will flash and the internal buzzer will sound.
To Accept the Fault and silence the buzzer, press the “ACCEPT /
LAMP TEST” button.
If the fault is detected on one of the output zones (such as an
Amplifier or Loudspeaker Line Fault) a Fault may be indicated on
the relevant Zone’s LCD Display, however this depends on the
Fault Reporting configuration settings.
Depending on the nature of the fault it could prevent an
announcement from being broadcast to the affected zone.
Remedial action should be taken as soon as possible to correct
faults as they impair the correct operation of the system.
4.5.2 BVRD Series Microphones Fault Indicators
The BVRD Series Microphones include three fault indicators to
show the following faults:
• “COMMS FAULT”: The BVRD Microphone cannot
communicate with the system via RS485 data. The only
function that will operate is the “PRIORITY ALL CALL”
bypass (item "F" in Figure 4.1) if fitted.
• “PROCESSOR FAULT”: The BVRD Microphone has
suffered a processor fault and is not operating correctly. The
only function that will operate is the “PRIORITY ALL CALL”
bypass (item "F" in Figure 4.1) if fitted.
• “RESTART”: The Processor has restarted since power has
been applied. This will appear when first switched on and can
be reset by pressing the “ACCEPT/LAMP TEST” button.
N
OTE
: The specific level of Fault Reporting on the BVRD Microphone is
set during Configuration.