BVRD Series Microphones
Installation Instructions
10
BVRD Series Microphones issue 5
3.5 T
EMPORARY
“B
UZZER
M
UTE
”
To temporarily silence the fault buzzer use the following
procedure:
1. Disconnect the RJ45 network cable.
2. Turn the “Emergency Mode” Keyswitch 45°, and press and
hold the DVA message “HOME” button.
3. Reconnect the RJ45 cable (to reconnect power).
4. Press the “HOME” button until the “OK” LED illuminates.
5. Release the “HOME” button.
3.6 F
AULT
F
INDING
: R
E
-
SCAN
P
ROCEDURE
If the LCD Zone Displays do not show the correct (or any) zone
information then perform the following procedure:
This forces a rescan to detect the correct number of zone buttons.
1. Turn the “Emergency Mode” Keyswitch 45°, and press and
hold the DVA message “HOME” button.
2. Press and release the “Fault Accept” button.
3. Release the “Home” button and turn off the keyswitch.
N
OTE
: The buzzer will remain muted until the RJ45 cable is disconnected
or power removed. While the Buzzer is muted the "OK" LED will be
permanently illuminated,
N
OTE
: This procedure only applies to units using Firmware V1.06 or
earlier (supplied before batch number 25192 or March 2011).
Later versions of firmware have the zone information set during
configuration.