5
Feature
Description
Motor Overload (I
2
t) with RMS Current Limit
Provides motor overload protection which prevents motor burnout and eliminates
nuisance trips. UL approved as an electronic overload protector for motors.
Electronic Inrush Current Limit (EICL™)
Eliminates harmful inrush AC line current during startup.
Short Circuit
Prevents drive failure if a short circuit occurs at the motor (phase-to-phase).
Regeneration
Eliminates nuisance tripping due to high bus overvoltage caused by rapid deceleration
of high inertial loads.
Undervoltage and Overvoltage
Shuts down the drive if the AC line input voltage is outside the operating range.
MOV input transient suppression
Prevents failure of power devices caused by voltage spikes in the AC line.
Microcontroller
Self Monitoring and Auto-Reboot.
TABLE 3 – PROTECTION FEATURES
Trimpot
Minimum Speed (MIN)
Sets the minimum motor speed.
Offset (OFFSET)
Sets the minimum motor speed.
Maximum Speed (MAX)
Sets the maximum motor speed.
Acceleration (ACC)
Sets the motor acceleration time (time to reach full speed).
Deceleration (DEC/B)
Sets the motor deceleration time (time to reach zero speed).
Slip Compensation (COMP)
Maintains set motor speed under varying loads.
Boost (DEC/B)
Sets the Volts/Hz Curve for 50 Hz motors to obtain maximum performance.
Current Limit (CL)
Sets the current limit and limits the maximum current (torque) to the motor.
TABLE 4 – TRIMPOT ADJUSTMENTS
Accessory
Description
Signal Isolator and Run/Fault Relay
(Catalog No. ID5SI-1)
Provides isolation between a non-isolated signal voltage (0 to ±25 Volts DC)
or current source (4 – 20 mA DC) and the drive. Mounts on the end of the drive. This
option is built-in on Catalog Nos. ID5401-CO, ID5402-CO, ID5403-CO, ID5405-CO.
TABLE 5 – OPTIONAL ACCESSORY
TABLE 6 – ELECTRICAL RATINGS*
Catalog
No.
AC Line Input
Fuse or
Circuit
Breaker
Rating
(Amps)
Drive Output
Net Wt.
Nominal
Volts AC
(50/60 Hz)
Phase
(
φ
)
Maximum
Current
(Amps AC)
Output
Voltage Range
(Volts AC)
Maximum
Continuous
Load Current
(RMS mps/Phase)
Maximum
Horsepower
(HP (kW))
Lbs.
kg
ID5202-CO
208/230
1
17.0
20
0 – 230
6.7
2 (1.5)
4.1
1.9
3
8.0
10
ID5203-CO
1
208/230
3
10.8
15
0 – 230
9.0
3 (2.25)
4.6
2.1
ID5401-CO
400/460
3
2.4
5
0 – 400/460
2.0
1 (.75)
4.1
1.9
ID5402-CO
400/460
3
3.9
5
0 – 400/460
3.3
2 (1.5)
4.1
1.9
ID5403-CO
2
400/460
3
5.3
10
0 – 400/460
4.6
3 (2.25)
4.1
1.9
ID5405-CO
1,2
400/460
3
9.6
15
0 – 400/460
8.3
5 (3.75)
4.6
2.1
Notes: 1.
Catalog Nos. ID5203-CO, ID5405-CO contain built-in cooling fan.
2.
Catalog Nos. ID5401-CO, ID5402-CO, ID5403-CO, ID5405-CO are
rated 0 – 400 Volts AC for 50 Hz motor operation and 0 – 460 Volts AC for 60 Hz motor operation.
*All models contain a Terminal Block for AC line and motor connections. The Signal Isolator and Run/Fault Relay is standard on Catalog Nos.
ID5401-CO, ID5402-CO, ID5403-CO, ID5405-CO and optional on Catalog Nos. ID5202-CO, ID5203-CO.
Summary of Contents for SERIES 5
Page 29: ...NOTES 29...
Page 30: ...NOTES 30...