In the Manual Start Mode,
the drive will trip due to all
faults (Overvoltage,
Undervoltage, Short Circuit,
and I
2
t) and remain tripped
even when the fault is
cleared. To Start/Reset the
drive, the switch or contact
must be manually closed.
Also, the drive must be
restarted each time the AC
line is interrupted.
For
Automatic Start
, see Section
6.2, on pages 21 and 22.
Notes: 1.
See Section 8.3, on page
27. Also see Section 9.2, on page
28.
2.
The drive can be factory pro-
grammed for Run/Stop operation
with momentary contacts.
5.7 Forward-Stop-Reverse Switch
Connection (CON2):
The drive can
operate using a Forward-Stop-
Reverse Switch, Contact, or Open
Collector.
1. Catalog Nos. ID5202-CO,
ID5203-CO:
Remove the factory
installed jumper on CON2 and
install the 3-wire connector (sup-
plied). CON2 is located on the
lower PC board. Connect a
“maintained” switch or contact to
the 3-wire connector. See Figure 14. Also see Forward/Reverse Speed Selection, in
Section 6.3, on page 22.
If installing the ID5SI-1 Signal Isolator, See number 2.
Note:
The drive can be factory programmed for momentary contact operation.
2. Catalog Nos. ID5401-CO, ID5402-CO, ID5403-CO, ID5405-CO:
Connect the
Forward-Stop-Reverse Switch as shown in Figure 8, on page 17. If using Form “C”
Contact or Relay, connect the circuit as shown in Figure 15. If using Open Collector,
connect the circuit as shown in Figure 16.
5.8 Enable Switch Connection (CON2):
The drive can be started and stopped with an
Enable Switch (close to run, open to stop). Remove the factory installed jumper on
CON2 and install the 3-wire connector (supplied). CON2 is located on the lower PC
board. Connect a “maintained” switch or contact to the 3-wire connector. See Figure 17,
on page 20.
REV
-5V
TB
1
+5V
0V
FWD
SIG1
COM1
Forward
Reverse
ID5SI-1
TERMINAL
BLOCK
FIGURE 15 – FORM “C” CONTACT OR RELAY
FORWARD-STOP-REVERSE CONNECTION
REV
-5V
TB
1
+5V
0V
FWD
SIG1
COM1
Forward
Reverse
ID5SI-1
TERMINAL
BLOCK
FIGURE 16 – OPEN COLLECTOR
FORWARD-STOP-REVERSE CONNECTION
FIGURE 14 – FORWARD-STOP-REVERSE SWITCH CONNECTION
Jumper Removed
Connector Installed for
Forward-Stop-Reverse Switch
CON2
F - S - R
Forward-Stop-Reverse
Black
White
CON2
Red
Stop
Forward
Reverse
Switch