17
2. Catalog Nos. ID5401-CO,
ID5402-CO, ID5403-CO,
ID5405-CO:
Connect the
Main Speed Potentiometer
to Terminal Block TB1 on
the ID5SI-1.
Unidirectional Speed
Operation:
Connect the
Main Speed Potentiometer
to Terminals “+5V” (high),
“SIG1” (wiper), “COM1”
(low). Motor direction is
selected with a Forward-
Stop-Reverse Switch
connected to Terminals “0V”
(common of switch), “FWD”,
“REV”. See Figure 8. If a
Forward-Stop-Reverse
Switch is not used, a jumper
must be installed between
Terminals “0V” and “FWD”,
of Terminal Block TB1, in
order for the drive to
operate.
Bidirectional Speed
Operation:
Connect the
Main Speed Potentiometer to
Terminals “+5V” (high), “SIG1”
(wiper), “– 5V” (low). Terminals
“FWD”, “REV”, “COM1” must be
connected together. See Figure 9.
5.5 Signal Following Connections:
The
drive output will linearly follow the analog
signal input.
Catalog Nos. ID5202-CO, ID5203-CO:
Connect the
isolated*
0 – 5 Volt DC
signal input positive lead (+) to Terminal “P2” and the negative lead (–) to Terminal “P1”.
The terminals are located on the lower PC board. With external circuitry, a 0 – 10 Volt DC
analog signal can also be used. See Figure 10.
*If a non-isolated signal is used, install the ID5SI-1 Signal Isolator. The ID5SI-1 accepts volt-
age (0 to ±25 Volts DC) or current (4 – 20 mA DC) signal inputs. See Table 5, on page 5.
Note:
For signal following operation, the Minimum Speed Trimpot (MIN) must be set fully
counterclockwise.
REV
High
Stop
-5V
TB
1
+5V
0V
FWD
Forward
Wiper
Potentiometer
Main Speed
(5 k)
Low
Reverse
SIG1
COM1
ID5SI-1
TERMINAL
BLOCK
CU
R
VO
LT
J1
FIGURE 8 – UNIDIRECTIONAL MAIN SPEED POTENTIOMETER
& FORWARD-STOP-REVERSE SWITCH CONNECTIONS
(Jumper J1 Installed in “VOLT” Position)
REV
-5V
TB
1
+5V
0V
FWD
SIG1
COM1
Main Speed
Potentiometer
Wiper
(5 k)
High
Jumper
Low
Jumper
CU
R
VO
LT
J1
ID5SI-1
TERMINAL
BLOCK
FIGURE 9 – BIDIRECTIONAL
MAIN SPEED POTENTIOMETER CONNECTION
(Terminals “FWD”, “REV”, “COM1” Connected)
(Jumper J1 Installed in “VOLT” Position)
FIGURE 10 – CATALOG NOS. ID5202-CO, ID5203-CO
VOLTAGE FOLLOWING SIGNAL INPUT CONNECTION
0 – 5 Volts DC (Isolated)
0 – 10 Volts DC (Isolated)
P1
P2
P3
0 - 5
Volts DC
+
-
V
P1
P2
P3
0 - 10
Volts DC
V
+
-
10k
10k
Summary of Contents for SERIES 5
Page 29: ...NOTES 29...
Page 30: ...NOTES 30...