TABLE 3 - PROTECTION FEATURES
Feature Description
Motor Overload (I
2
t) with RMS Current Limit
Provides motor overload protection which
prevents motor burnout and eliminates
nuisance trips*.
Electronic Inrush Current Limit (EICL™)
Eliminates harmful inrush AC line current
during startup.
Short Circuit
Shuts down the drive if a short circuit
occurs at the motor (phase-to-phase).
Regeneration
Eliminates tripping due to bus overvoltage
caused by rapid deceleration of high
internal loads.
Undervoltage and Overvoltage
Shuts down the drive if the AC line input
voltage goes above or below the
operating range.
MOV input transient suppression.
Prevents failure of power devices caused
by voltage spikes in the AC line.
Microcontroller Feature
Self monitoring and auto-reboot.
* UL approved as an overload protector for motors.
TABLE 4 – SELECTABLE JUMPERS (See Section 6, on page 19)
Feature Description
AC Line Input Voltage Selection (115/230 Volts AC)
J1. Refer to Section 6.1, page 19.
Factory set for 208/230 VAC (Install
Jumper for 115 VAC Operation).
Motor Horsepower (1/8, 1/4, 1/2, 3/4, 1 HP) J2.
Refer to Section 6.2, page 19.
Selectable for the motor use.
Automatic or Manual Start and Reset. J3.
Refer to Section 6.3, page 19.
Factory set for Auto. Can be set for
Automatic start or Manual start (Optional
FSR Switch required).
Motor Frequency (50/60 Hz) J5.
Frequency Multiplier (1X, 2X) J4.
Refer to Sections 6.4.1 and 6.4.2, on page 20.
Factory set for 60 Hz. Must be set for the
motor being used. In addition, the drive
may be set for up to 2X the motors rated
RPM.
“Run” or “Fault” Output Relay Operation. J6, Refer
to Section 6.5, page 20.
Factory set to RUN position. Set to either
Run or Fault for intended application.
TABLE 5 - TRIMPOT ADJUSTMENTS (See Section 7, on pages 21 – 24)
Trimpot Description
Minimum Speed (MIN), Refer to Section 7.1, page
21.
Sets the minimum speed of the motor.
Maximum Speed (MAX), Refer to Section 7.2, page
22.
Sets the maximum speed of the motor.
Acceleration (ACCEL), Refer to Section 7.3, page
22.
Sets the amount of time for the motor to
accelerate from zero speed to full speed.
Deceleration (DECEL), Refer to Section 7.4, page
22.
Sets the amount of time for the motor to
decelerate from full speed to zero speed.
Slip Compensation (COMP) Refer to Section 7.5,
page 22.
Sets the amount of Volts/Hz to maintain set
motor speed under varying loads.
Current Limit (CL), Refer to Section 7.6, page 23.
Sets the current limit and limits the
maximum current (torque) to the motor.