Hardware Features
MN1258V4 08/2000
15
Associated MINT keywords are:
#INx, INPUTACTIVELEVEL, IN, INx, INPUTMODE, INPUTNEGTRIGGER,
INPUTPOSTRIGGER, INSTATE
3.4.2
Fast Interrupts: J6
Pin No
Signal
Function
1
fast-int 0
Fast interrupt 0
2
chassis
Chassis ground for cable screen
3
usr-com
Common reference
4
fast-int 1
Fast interrupt 1
5
chassis
Chassis ground for cable screen
6
usr-com
Common reference
7
fast-int 2
Fast interrupt 2
8
chassis
Chassis ground for cable screen
9
usr-com
Common reference
10
fast-int 3
Fast interrupt 3
Interrupt inputs may be 12 to 24V positive or negative with respect to
usr-com
.
usr-com
is shared
with the digital inputs.
There is a facility for 4 high speed external interrupts on NextMove BX. These are isolated using
high speed opto-isolators and full bridge rectification. They are driven in the same way as the digital
inputs, see the digital input section for details on the voltage levels. The interrupt inputs can cause an
interrupt on both activating and deactivating edges of the signal. Fast interrupt 0 has a maximum
latency of 30µs. Fast interrupts 1 to 3 have a maximum latency of 1ms.
Because of the fast response time of the input circuitry (approx. 200ns)these inputs are more
susceptible to high frequency noise. Care must be taken with shielding/screening and routing of these
signals, i.e. do not route high speed interrupt cabling near motor drive cabling.
Figure 3-6: Fast Interrupt Input Circuit
See section ‘Fast Position Latch’ in the ‘Mint v4 Programming Guide’ for more details.
Summary of Contents for NextMove BX
Page 1: ...MN1258V4 08 2000 NextMove BX Installation Manual for Mint v4 Issue 4 0...
Page 2: ...NextMove BX Installation Manual for Mint v4 ii MN1258V4 08 2000...
Page 4: ...NextMove BX Installation Manual for Mint v4 iv MN1258V4 08 2000...
Page 8: ...NextMove BX Installation Manual for Mint v4 viii MN1258V4 08 2000...
Page 12: ...NextMove BX Installation Manual for Mint v4 xii MN1258V4 08 2000...
Page 18: ...NextMove BX Installation Manual for Mint v4 6 MN1258V4 08 2000...
Page 22: ...NextMove BX Installation Manual for Mint v4 10 MN1258V4 08 2000 Figure 3 3 Board Settings...
Page 46: ...NextMove BX Installation Manual for Mint v4 34 MN1258V4 08 2000...
Page 78: ...NextMove BX Installation Manual 66 MN1258V4 08 2000...
Page 82: ...NextMove BX Installation Manual 70 MN1258V4 08 2000...
Page 88: ...NextMove BX Installation Manual 76 MN1258V4 08 2000...
Page 92: ...NextMove BX Installation Manual 80 MN1258V4 08 2000...
Page 94: ...NextMove BX Installation Manual 82 MN1258V4 08 2000...