CAUTION! Disconnect motor leads (A- and A+) from control before performing a “Leakage
Resistance” test on the motor. Failure to disconnect motor from the control may
result in extensive damage to the control. The control is tested at the factory for
high voltage/leakage resistance as part of Underwriters Laboratories
requirements.
CAUTION! Instantaneously applying the Hi-Pot voltage will cause irreversible damage to the
control.
CAUTION! Suitable for use on a circuit capable of delivering not more than 5,000 RMS
symmetrical short circuit amperes listed here at rated voltage.
CAUTION! Proper shielding, grounding, and filtering of this product can reduce the emission
of radio frequency interference (RFI) which may adversely affect sensitive
electronic equipment.
CAUTION! The Voltage Select Switch setting must match the actual AC line input voltage.
Verify that the Voltage Select Switch is in the correct position (“115” position for
115 Volt AC line input and “230” position (factory setting) for 208/230 Volt AC line
input). Do not use the “115V” position for 208/230 Volt AC line input voltage or
damage will occur to the control.