15
1.5 General Performance Specifications
Table 1-5 outlines the general performance specifications of the BC140 / BC140-FBR control.
Table 1-5 General Performance Specifications
1
Description
Specification
Factory
Setting
Speed Range (Ratio)
50:1
—
Armature Feedback Load Regulation (0 - Full Load, 50:1 Speed Range) (%
Base Speed)
1
2
—
Line Voltage Regulation (at Full Load, ± 10% Line Variation) (% Base Speed)
0.5
2
—
Control Linearity (% Speed vs. Dial Rotation)
2
—
Acceleration (ACCEL) Trimpot Range (Seconds)
0.2 - 10
2
Deceleration (DECEL) Trimpot Range (Seconds)
0.2 - 10
2
Maximum Speed (MAX) Trimpot Range (% Base Speed)
50 - 110
2
100
Minimum Speed (MIN) Trimpot Range (% Base Speed)
0 - 30
2
0
CL/Torque Range (% Full Load)
0 - 200
150
IR Compensation (IR) Trimpot Range (at Specified Full Load at 90/180 Volts
Output) (Volts DC)
0 - 24 / 0 - 48
3 / 6
Operating Temperature Range without Optional Auxiliary Heat Sink (Catalog
No. BC143) (
°
C /
°
F)
0 - 40 / 32 - 104
—
Operating Temperature Range with Optional Auxiliary Heat Sink (Catalog No.
BC143) (
°
C /
°
F)
0 - 50 / 32 - 122
—
Notes:
1. CE Compliance requires BC24-LF RFI Filter. (See Optional Accessories, Table 1-2).
2. Performance is for 90 Volt PM motors with 115 Volt AC line input and 180 Volt DC PM motors with 230
Volt AC line input.