Table 10-2 provides information on symptoms, possible causes, and the suggested corrective action for
controls with optional forward-brake-reverse switch installed.
Table 10-2 Troubleshooting Guide for Controls with Optional Forward-Brake-Reverse Switch Installed
Symptom
Possible Cause
Suggested Corrective Action
Motor will not run in
Forward or Reverse
direction.
Faulty wiring or loose connections
to the reversing switch.
Correct the connections. See
Figure 12-1.
Forward-Brake-Reverse defective.
Switch is defective.
Replace Forward-Brake-Reverse
Switch assembly.
No braking action in brake
mode.
Faulty connections or loose
connections.
Check and correct connections.
Defective Brake Resistor.
Replace Forward-Brake-Reverse
Switch assembly.