2-3
MN703
Table 2-2 Armature and AC Line Fuse Chart
Motor Horsepower
Approximate Motor
Current (Amps DC)
Fuse Selection
(AC Amps)
90VDC
180VDC
Armature
Line
1/100
1/50
0.2
0.5
12
1/50
1/25
0.3
0.5
12
1/30
1/15
0.33
0.5
12
1/20
1/10
0.5
0.75
12
1/15
1/8
0.8
1
12
1/12
1/6
0.85
1.25
12
1/8
1/4
1.3
2
12
1/6
1/3
2
2.5
12
1/4
1/2
2.5
4
12
1/3
3/4
3.3
5
12
1/2
1
5.0
8
12
3/4
1½
7.5
12
12
1*
2*
10
15
25
*With optional Auxiliary Heat Sink (Catalog No. BC143).
Table 2-3 Field Connection (Shunt Wound Motors Only)
AC Input Voltage
(Volts AC)
Voltage Selector
Switch (Position)
Armature Voltage
(Volts DC)
Field Voltage
(Volts DC)
Terminal
Connections
115
115
0 – 90
100
F+, F-
50
F+, L1
208/230
230
0 – 180
200
F+, F-
0 – 90*
100
F+, L1
Plug-In Horsepower Resistor®
A Plug-In Horsepower Resistor® (supplied separately) must be installed to match the control to the
motor so the IR Compensation and Current Limit settings to be correct. Select the proper Plug-In
Horsepower Resistor® according to Table 2-3. Plug-In Horsepower Resistors® are available from
your distributor. Install the Plug-In Horsepower Resistor®, as shown in Figure 2-3.
Note: Be sure the Plug-In Horsepower Resistor® is inserted completely into the mating sockets.
Table 2-4 Plug-In Horsepower Resistor® and Armature Fuse Kit Information
Motor Horsepower
Approximate
Motor Current
(ADC)
Plug-In HP Resistor® and
Armature Fuse Kit
Armature
VDC
90 – 130
Armature
VDC
180
Plug-In HP
Resistor Value
(Ohms)
Armature Fuse Rating
(Amps)
Catalog No.
1/100
1/50
0.2
1.0
0.5
BR1000
1/50
1/25
0.3
0.51
0.5
BR0510
1/30
1/15
0.33
0.35
0.5
BR0350
1/20
1/10
0.5
0.25
0.75
BR0250
1/15
1/8
0.8
0.25
1
BR0251
1/12
1/6
0.85
0.18
1.25
BR0180
1/8
1/4
1.3
0.1
2
BR0100
1/6
1/3
2
0.1
2.5
BR0101
1/4
1/2
2.5
0.05
4
BR0050
1/3
3/4
3.3
0.035
5
BR0035
1/2
1
5
0.025
8
BR0025
3/4
1½
7.5
0.015
12
BR0015SP
1*
2*
10
0.01
15
BR0010SP