TP200 

USER GUIDE   

     

42369 Rev A2

2

1

Balboa Water Group   |   Your Single Source Solution

RED LCD CHARACTERS 

Red indicates flashing or changing characters. For example, these 
segments flash when you press the TEMP button to change the Set 
Temperature. 

BLUE LCD CHARACTERS

Blue indicates an alternating message or a progressive message. 
When you view Time-of-Day, this progressive message appears.

TEMPERATURE BUTTON

The TEMP button icon indicates an “action.” For example, pressing 
the TEMP button initiates any one of the following actions: adjusting 
the Set Temperature, menu navigation, setting the Filter Cycle Time, 
setting the Heat Mode, etc. 

LIGHT BUTTON

The LIGHT button icon indicates navigation or a selection.

HOLLOW DOTS

Hollow dots indicate that your last setting was not saved. For 
example, when you set a feature such as Time-of-Day, you need to 
press the LIGHT button to save your setting. If you do not press the 
LIGHT button, the Main Screen will appear automatically after a few 
moments, and your last setting will not be saved.

SOLID DOTS

Solid dots indicate that your last setting will be saved. For example, if 
you change the Set Temperature and pause a few moments, the Main 
Screen will appear automatically, and your setting will be saved. The 
same applies to other features that will be discussed later.

DASHED LINE AROUND THE DISPLAY

Dashed lines indicate a Menu item that depends on a manufacturer 
configuration and may or may not appear. 

TABLE OF CONTENTS

SEQUENCE KEY

02

 SEQUENCE 

KEY

03

 

PANEL INTERFACE  & TERMINOLOGY

04

 

MAIN MENUS & NAVIGATION

05

 

SET TIME-OF-DAY

06

 

CHANGE SET TEMPERATURE

07

 

SET FILTER CYCLE TIMES

09

 

RESTRICT OPERATIONS

13

 

INVERT DISPLAY

14

 

HOLD MODE (STANDBY)

16

 

LIGHT TIMER PROGRAMMING 

17

 

SPA BEHAVIOR

19

 

HEAT SETTINGS 

23

 

FILL IT UP!

25

 

PANEL MESSAGES

27

 GENERAL

29

 

HEATER RELATED

31

 

TEMPERATURE SENSOR RELATED 

33

 MISCELLANEOUS

34

 

CONTROL SYSTEM RELATED 

36

 REMINDER

39

 PREFERENCES

42

 

DISPLAY F° OR C°

43

 

TURN ON/OFF REMINDERS DISPLAY

44

 

SET 12 OR 24 HOUR CLOCK

45

 

SET CLEANUP CYCLE DURATION

46

 

TURN ON/OFF M8

47

 UTILITIES

50 

INFORMATION SUBMENU

51

 

GFCI TEST FEATURE

55

 

FAULT LOG

57

 

TEMPERATURE SENSOR READINGS

Summary of Contents for TP200 PANEL

Page 1: ...TP200 PANEL User Guide Standard Menu Your Single Source Solution 42369 Rev A1 ...

Page 2: ...ng Balboa Water Group spa controls Please visit us at www BalboaWaterGroup com BP CONTROL SYSTEM Software Version 7 0 and later This user guide applies to TP200 TP240 and TP260 panels TP200 PANEL TP240 PANEL TP260 PANEL ...

Page 3: ... after a few moments and your last setting will not be saved SOLID DOTS Solid dots indicate that your last setting will be saved For example if you change the Set Temperature and pause a few moments the Main Screen will appear automatically and your setting will be saved The same applies to other features that will be discussed later DASHED LINE AROUND THE DISPLAY Dashed lines indicate a Menu item...

Page 4: ...ou do not press any buttons for a few moments the Main Screen will appear automatically PANEL INTERFACE TERMINOLOGY A B D F E TEMP TEMP is an umbrella term that refers to panel buttons that control temperature For example TEMP refers to these buttons B E TEMP Button s In addition to controlling the Set Temperature use the TEMP buttons to initiate actions while changing various settings LIGHT Butto...

Page 5: ...nge the Set Temperature When using a panel with WARM and COOL temperature buttons pressing either WARM or COOL will cause the Set Temperature to flash Pressing a temperature button again will adjust the Set Temperature in the direction indicated on the button When the LCD stops flashing the spa will heat to the new Set Temperature when required If the panel has a single temperature button pressing...

Page 6: ...pear SEQUENCE KEY View page 2 for full description Filter Cycle 2 In this example we will do the following Turn On Filter Cycle 2 View the current start time View the duration Set the start time to 8 00 AM Set the duration to 3 hours This means Filter Cycle 2 will end at 11 00 AM Follow the same sequence to set Filter Cycle 2 on your spa Filter Cycle 2 is optional It is Off by default on most cont...

Page 7: ...and the Main Screen will appear Or pause a moment and the Main Screen will appear automatically Main Screen SEQUENCE TP200 USER GUIDE 42369 Rev A2 10 9 Balboa Water Group Your Single Source Solution Press the TEMP button The Set Temperature will appear and flash While the Temperature is flashing press LIGHT until LOCK appears Press the TEMP button Press the LIGHT button to select Panel Lock not Te...

Page 8: ...ill not be saved and the Main Screen will appear momentarily Main Screen Unlock Temperature Settings Follow this sequence to unlock the temperature and settings This unlock sequence may be used from any screen that may be displayed on a restricted panel NOTE If the panel has a WARM and a COOL temperature button view page 3 only the WARM button will work in the Unlock Sequence Press the TEMP button...

Page 9: ...entarily Follow the same sequence to restore the default display orientation B Main Screen TP200 USER GUIDE 42369 Rev A2 14 13 Balboa Water Group Your Single Source Solution HOLD MODE HOLD MODE Follow this sequence activate Hold Mode Hold Mode is used to disable the pumps during service functions like cleaning or replacing the filter This mode will last for 1 hour unless it is exited manually by p...

Page 10: ...t Timer is On This means you are about to set the start time of the Light Timer Press TEMP to view the start time Press TEMP change the Hour from 7 to 8 Press LIGHT to select the minutes Press TEMP to change the minutes from 45 to 00 Press LIGHT to save your setting and RUN HRS will appear This message means you are about to set the duration Use the same sequence to set the duration This message m...

Page 11: ...ed and high speed if equipped If left running Pump 1 will turn off after a time out period The heater pump will run when the blower or any other pump is on If the spa is in Ready Mode view page 20 Pump 1 low may also activate for at least 1 minute every once in a while to detect the spa temperature polling and then to heat to the set temperature if needed When the low speed turns on automatically ...

Page 12: ...bably want to use Ready Mode 2 REST MODE Rest Mode only heats the water during filter cycles If you do not use your spa for an extended period of time you may want to use Rest Mode 3 READY IN REST MODE This mode is a subfeature of Rest Mode When your spa is in Rest Mode and you press the JETS button Rest Mode will automatically switch to Ready In Rest Mode for one hour During this hour the control...

Page 13: ... press LIGHT your setting will not be saved and the Main Screen will appear momentarily NOTES REST MODE When the spa is in REST Mode REST the Main Screen will alternate between displaying the water temperature and REST READY IN REST MODE If you press the JETS button while in Rest Mode the spa will switch to Ready In Rest Mode RRST for one hour The Main Screen will alternate between displaying the ...

Page 14: ...les or the flow from one pump may hide the flow from another pump TP200 USER GUIDE 42369 Rev A2 24 23 Balboa Water Group Your Single Source Solution FILL IT UP Follow these steps to prime a two speed pump Press the button for that pump once to turn it On at low speed Press the button again to run the pump at high speed Run the pump at high speed for 2 minutes If priming is not complete after 2 min...

Page 15: ... is with a troubleshooting scenario For example what happens if the spa water overheats The panel will display this message A The control system will capture the following information and save it in a fault log Time Of Day Water temperature Set Temperature The number of days that have passed since the water overheated Temperature Range Heat Mode Message Code B The Message Code links the Panel Mess...

Page 16: ...or instructions on how to review the Fault Log that corresponds with the Message Code This message can be reset from the panel with any button press The spa water is too hot One of the water temperature sensors has detected a spa water temperature of 110 F 43 3 C so spa functions are disabled The Control System will automatically reset when the spa water temperature is below 108 F 42 2 C Extended ...

Page 17: ...s with the Message Code This message can be reset from the panel with any button press The heater may be dry Possible dry heater or not enough water in the heater to start it The spa is shut down for 15 minutes Press any button to reset the heater start up See Water Flow Check List on page 28 Message Code Heater is dry There is not enough water in the heater to start it The spa is shut down After ...

Page 18: ...message appears in the panel display this fault has been established for at least 1 hour Contact your dealer or service organization Message Code Temperature sensor A has failed Either temperature sensor A or the sensor circuit has failed Contact your dealer or service organization Message Code Temperature sensor B has failed Either temperature sensor B or the sensor circuit has failed Contact you...

Page 19: ...de Memory Warning Persistent Memory Reset Appears after any system setup change Contact your dealer or service organization if this message appears on more than one power up or if it appears after the system has been running normally for a period of time Message Code Clock Error The clock that keeps track of time when the spa is powered Off has failed Contact your dealer or service organization No...

Page 20: ...h a pH test kit and adjust pH with the appropriate chemicals General maintenance helps your spa Reminder messages alternate with the Main Screen Reminder Messages can be chosen individually by the Manufacturer They may be disabled entirely or there may be a limited number of Reminders on a specific model The frequency of each Reminder i e 7 days can be specified by the Manufacturer Press a Tempera...

Page 21: ...ed and conditioned for maximum life Change the mineral cartridge as needed Install a new mineral cartridge per you spa manufacturer s instructions Test the GFCI or RCD This message may appear every 30 days The Ground Fault Circuit Interrupter GFCI or Residual Current Device RCD is an important safety device and must be tested on a regular basis to verify its reliability Every user should be traine...

Page 22: ...Fine tune your spa s settings 40 39 TP200 USER GUIDE 42369 Rev A2 Balboa Water Group Your Single Source Solution PREFERENCES ...

Page 23: ...w will appear in a moment Press LIGHT to view UTIL Or pause a moment and the Main Screen will appear SEQUENCE Main Screen PREFERENCES PREFERENCES MENU PREFERENCES DISPLAY F OR C Turn On Off M8 Switch the clock between 12 hour and 24 hour displays Turn On Off reminders Set the cleanup cycle duration Press TEMP to view the current address number for the Dolphin II or Dolphin III In this example the ...

Page 24: ...Reminders is On If you pause for a moment the Main Screen will appear automatically and the Reminders setting will remain YES If you want to change the setting to NO press TEMP NO indicates that the Reminders setting will be turned Off Press the LIGHT button to save your setting Press LIGHT to view UTIL Or pause a moment and the Main Screen will appear SEQUENCE Press the TEMP button The Set Temper...

Page 25: ... appear Follow this sequence to view the current Cleanup Cycle duration or change the duration The duration can be set from 0 4 hours in 30 minute increments The heater pump will run during a Cleanup Cycle View page 18 for more information on the heater pump Cleanup Cycle is not available on all control systems SEQUENCE Main Screen Follow this sequence to view the current M8 setting and to change ...

Page 26: ...48 47 TP200 USER GUIDE 42369 Rev A2 Balboa Water Group Your Single Source Solution Helpful tools and information for spa technicians UTILITIES ...

Page 27: ...tion setup number Configuration signature 120V or 240V input voltage sensed by a UL control system at startup Heater type DIP switch 1 setting 0 test mode On 1 test mode Off DIP switch 2 3 4 settings the number of HS pumps with heat This is the panel software version Main Screen Press the TEMP button The Set Temperature will appear and flash While the Set Temperature is flashing press LIGHT until ...

Page 28: ...hnician should Manually verify that a GFCI breaker is installed and that the circuit and spa are wired correctly Verify the function of the GFCI with its own test button Restore power to the spa and repeat the GFCI Trip Test Once the GFCI is tripped by the test reset the GFCI and the spa will operate normally from that point You can verify a successful test by following the sequence on page 54 PAS...

Page 29: ...it will need to be re tested after installation at the new location Flashing characters Progressive message Press TEMP button for action Press LIGHT button to select Pause back to Main Screen setting not saved Pause back to Main Screen setting saved Menu Items may or may not appear SEQUENCE KEY View page 2 for full description SEQUENCE GFCI TEST STATUS Main Screen Follow this sequence to check the...

Page 30: ...tion can help spa technicians diagnose and fix issues The sequence on the next page shows how to view the fault log Not every entry in the Fault Log is an actual fault For example message code MO19 is inserted into the fault log to identify each time the spa restarts Each time a fault occurs it is assigned a unique number starting with number 1 The next fault is assigned number 2 and so on Up to 2...

Page 31: ...ess the LIGHT button the Main Screen will appear and this feature will be On Temperature readings from sensor A and sensor B appear on the Main Screen The Main Screen displays temperature readings from sensor A and sensor B until you turn Off this feature Follow the same sequence to turn Off this feature Main Screen SEQUENCE Follow this sequence to view separate temperature readings from sensor A ...

Page 32: ...er differentiel avant d utiliser le bain Lire la notice technique Lorsque l appareillage est installe dans une fosse on doit assurer un drainage adequat Employer uniquement a l interieur d une cloture CSA Enclosure 3 Connecter uniquement a un circuit protege par un disjoncteur differentiel de Class A Afin d assurer une protection permanente contre le danger de shock electrique lors de l entretien ...

Page 33: ...ervice is available M F 7 00AM to 6 00PM PT Corporate Office Balboa Water Group 3030 Airway Avenue Costa Mesa CA 92626 MEXICO OPERATIONS Balboa Water Group Aguila Azteca 6011 Baja Maq El Aquila Mexico 22221 EUROPEAN OPERATIONS Balboa Water Group Hydroair International ApS Roustvej 50 DK 6800 Varde TP200 PANEL ...

Reviews: