Temp Set 

(80°F - 104°F / 26.0°C - 40.0°C)

The last measured temperature is constantly displayed 
on the LCD. Your spa’s set temperature range may 
vary from range shown above depending on your 
manufacturer’s settings.

Note that the last measured spa temperature displayed is 
current only when the pump has been running for at least 
1 minute.

Cool/Warm  

  

Press the “Cool” or “Warm” button once to display the 
set temperature. Each time either button is pressed again, 
the set temperature will increase or decrease depending 
on which button is pressed. After three seconds, 
the LCD will automatically display the last measured 
spa temperature.

Mode  

This button is used to switch between Standard, 
Economy, and Sleep modes. Press “Mode” to enter mode 
programming, press “Cool” to cycle through to desired 
mode (LCD flashes until confirmed), then press “Mode” 
to confirm selection.

Standard mode 

maintains the desired temperature. 

Note that the last measured spa temperature displayed 
is current only when the pump has been running for 
at least 1 minute. “

” will appear on the display 

momentarily when you switch into Standard Mode.

Economy mode

 heats the spa to the set temperature only 

during filter cycles. “

” will appear solid when the 

temperature is not current and will alternate with the 
temperature when the temperature is current.

Pressing “Jets 1” while in Economy mode puts the spa 
in 

Standard-In-Economy mode, 

(“

”) which

 

operates the 

same as Standard Mode, then reverts to Economy Mode 
automatically after 1 hour. During this time, pressing 
“Cool” or “Warm” followed by “Light” will revert the 
mode to Economy immediately.

Sleep mode

 heats the spa to within 20°F (11°C) of the set 

temperature only during filter cycles. “

” will appear 

on the display until mode is changed.

Standby Mode

Pressing “Cool” or “Warm” followed by “Blower” 
or “Jets 2” or “Aux” will turn off all spa functions 
temporarily. This is helpful when changing a filter. 
Pressing any button exits Standby mode. On some 
systems the “Jets 1” button will control the pump in 
Standby Mode (“Drain Mode”). In this case, press any 
other button to exit. System will revert to previous mode 
after 1 hour.

Jets 1  

Press the “Jets 1” button once to turn pump 1 on or off, 
and to shift between low and high speeds if equipped. 
If left running, the pump will turn off after a timeout 
period. The pump 1 low speed timeout on some systems 
may be as long as 4 hours.

On non-circ systems, the low speed of pump 1 runs 
when the blower or any other pump is on. It may also 
activate for at least 1 minute every 30 minutes to detect 
the spa temperature (polling) and then to heat to the 
set temperature if needed, depending upon mode. 
When the low speed turns on automatically, it cannot 
be deactivated from the panel; however, the high speed 
may be started.

Jets 2

 

 

 

(optional on some systems)

Press the “Jets 2” button once to turn pump 2 on or 
off, and to shift between low and high speeds if it is 
a two-speed pump. If left running, the pump will turn 
off after a timeout period.

Blower  

1-speed operation: on/off; 
2-speed operation: med/hi/off; or 
3-speed operation: lo/med/hi/off. 
If left on, the blower will automatically turn off after a 
timeout period.

Note: If your system does not have a “Blower” button, and 
is labeled as ”Jets 3” instead, please see page 9 “Jets 3”.

Light  

Some systems are equipped with both a spa light and a 
fiber optic light; however, only one can be accessed by this 
panel. (Larger panels may be purchased so that both the 
spa light and fiber optic light can be utilized.) Depending 
upon how your spa is equipped and configured, the 
“Light” button will operate in one of three ways:

1) Press the “Light” button to turn the spa light on and 
off, and to shift between dim and bright settings if your 
light is dimmable.

2) If a fiber-optic light with wheel is installed, press the 
“Light” button once to start the light and wheel, press 
it again to stop the wheel, and then again to turn the 
light off.

3) If a fiber-optic light without a separate wheel stop is 
installed, press the “Light” button to turn it on and off.

Again, both a spa light and a fiber optic light may be 
used simultaneously on the EL8000 and EL5000 systems 
with a different panel.

If any light is left on, it will automatically turn off after a 
factory programmed time period.

Page 2

Summary of Contents for GL Series

Page 1: ...h gh gh gh gh gh gh ght t h h h h h h h h h ht t t t t t t t t t t M M M Mo Mo Mo Mo Mo Mo Mo Mo Mod d d de de de de de de de de de Heat Heat Warm Light Warm Jets 1 Jets 2 Light Mode Cool Blower Note...

Page 2: ......

Page 3: ...automatically Certain conditions filters or freeze can cause a function to operate longer while faults can cause a function to operate for a shorter length of time The system keeps track of timeouts r...

Page 4: ...n this case press any other button to exit System will revert to previous mode after 1 hour Jets 1 Press the Jets 1 button once to turn pump 1 on or off and to shift between low and high speeds if equ...

Page 5: ...for details Locking Features If this panel is used as the main panel locking features will not be available If this panel is used as a remote or additional panel it will lock when the main panel is l...

Page 6: ...military format 00 00 is midnight 23 00 is one hour before midnight When set to time is displayed in 12 hour am pm format 12 00 is midnight 11 00 pm is one hour before midnight Clean up Cycle Duration...

Page 7: ...o select it Press the Warm button until is displayed Press Jets 1 to initiate the GFCI Trip Test The GFCI should trip within several seconds and the spa should shut down If it does not shut down the p...

Page 8: ...nce the heater has cooled reset by pushing any button If spa does not reset shut off the power to the spa and call your dealer or service organization DO NOT ENTER THE WATER Remove the spa cover and a...

Page 9: ...e and return to normal operation Temperature display is current after pump has been running for at least 2 minutes will appear solid on the display when the temperature is not current will alternate w...

Page 10: ...tructions Every 30 days Test reset GFCI per manufacturer s instructions Every 90 days Drain and refill spa per manufacturer s instructions Every 180 days Clean and condition cover per manufacturer s i...

Page 11: ...s installed press the Fiber button once to start the light and wheel press it again to stop the wheel and then again to turn the light off The fiber icon stands still when the fiber optic light is on...

Page 12: ...e spa s 2EAD THE INSTRUCTION MANUAL s DEQUATE DRAINAGE MUST BE PROVIDED IF THE EQUIPMENT IS TO be installed in a pit s OR USE ONLY WITHIN AN ENCLOSURE RATED 3 NCLOSURE s ONNECT ONLY TO A CIRCUIT PROTE...

Reviews: