background image

EL/GL SERIES (Mach 3) CONTROL WITH ML551/ML554 PANEL

The ML551 and ML554 panels can be used with the 
EL8000, EL5000, EL2000 and EL1000 systems. This user 
guide lists all features that are available. Your spa may 
not respond as described in this document as specific 
operation varies by system and equipment used. If your 
spa is not fully equipped, the panel buttons on your 
spa control may not be laid out as shown. Functions 
not accessible by this panel may be accessible by a 
larger panel such as the ML900. Example: The ML551 
and ML554 panels can be used with all EL8000 systems 
equipped with three pumps, but pump 3 cannot be 
controlled with this panel unless the system does not 
have a blower and an additional Jets button is added to 
the panel in its place. In other cases, pump 3 can be 
controlled with an optional auxiliary panel.

The pump responsible for heating and filtration (pump 1 
low on non-circ systems, or the circ pump on circ 
systems) will be referred to simply as the pump.

Timeouts refer to a preset length of time that a 
function is programmed to operate before shutting off 
automatically. Certain conditions (filters or freeze) can 
cause a function to operate longer, while faults can 
cause a function to operate for a shorter length of time. 
The system keeps track of timeouts regardless of other 
conditions occurring.

In multi-button sequences, if buttons are pressed too 
quickly in sequence, they may not register.

Table of Contents

EL/GL SERIES (Mach 3) CONTROL   . . . . .   1
Initial Start-up  . . . . . . . . . . . . . . . . . . . . .   1
Temp Set   . . . . . . . . . . . . . . . . . . . . . . . .   2
Cool/Warm  . . . . . . . . . . . . . . . . . . . . . . .   2
Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . .   2
Standby Mode  . . . . . . . . . . . . . . . . . . . . .   2
Jets 1   . . . . . . . . . . . . . . . . . . . . . . . . . . .   2
Jets 2   . . . . . . . . . . . . . . . . . . . . . . . . . . .   2
Blower  . . . . . . . . . . . . . . . . . . . . . . . . . .   2
Light  . . . . . . . . . . . . . . . . . . . . . . . . . . . .   2
Preset Filter Cycles   . . . . . . . . . . . . . . . . .   3
Freeze Protection   . . . . . . . . . . . . . . . . . .   3
Locking Features  . . . . . . . . . . . . . . . . . . .   3
 

 
Clean-up Cycle  . . . . . . . . . . . . . . . . . . . .   3
Circ Pump . . . . . . . . . . . . . . . . . . . . . . . .   4
Ozone . . . . . . . . . . . . . . . . . . . . . . . . . . .   4
Displaying Information About Your Spa  . .  4
User Preferences  . . . . . . . . . . . . . . . . . . .   4
Editing User Preferences  . . . . . . . . . . . . .   4
GFCI Protection . . . . . . . . . . . . . . . . . . . .   5
GFCI Trip Test Procedure   . . . . . . . . . . . .   5
Diagnostic Messages  . . . . . . . . . . . . . .   6-7
Periodic Reminder Messages  . . . . . . . . . .   8
Optional Auxiliary Panels   . . . . . . . . . . . .   9
Basic Installation Guidelines   . . . . . . . . .   10
CSA Compliance  . . . . . . . . . . . . . . . . . .  10

Page 1

Initial Start-up

When your spa is first actuated, it will go into Priming 
mode (after displaying some configuration information). 

Please see the M-7 Installation Instruction Manual for 
complete instructions on Power-up and Pump Priming.

The Priming mode will last for up to 4 minutes and 
then the spa will begin to heat and maintain the water 
temperature in the Standard mode. You can exit Priming 
mode early by pressing “Cool” or “Warm.”

Summary of Contents for GL Series

Page 1: ...h gh gh gh gh gh gh ght t h h h h h h h h h ht t t t t t t t t t t M M M Mo Mo Mo Mo Mo Mo Mo Mo Mod d d de de de de de de de de de Heat Heat Warm Light Warm Jets 1 Jets 2 Light Mode Cool Blower Note...

Page 2: ......

Page 3: ...automatically Certain conditions filters or freeze can cause a function to operate longer while faults can cause a function to operate for a shorter length of time The system keeps track of timeouts r...

Page 4: ...n this case press any other button to exit System will revert to previous mode after 1 hour Jets 1 Press the Jets 1 button once to turn pump 1 on or off and to shift between low and high speeds if equ...

Page 5: ...for details Locking Features If this panel is used as the main panel locking features will not be available If this panel is used as a remote or additional panel it will lock when the main panel is l...

Page 6: ...military format 00 00 is midnight 23 00 is one hour before midnight When set to time is displayed in 12 hour am pm format 12 00 is midnight 11 00 pm is one hour before midnight Clean up Cycle Duration...

Page 7: ...o select it Press the Warm button until is displayed Press Jets 1 to initiate the GFCI Trip Test The GFCI should trip within several seconds and the spa should shut down If it does not shut down the p...

Page 8: ...nce the heater has cooled reset by pushing any button If spa does not reset shut off the power to the spa and call your dealer or service organization DO NOT ENTER THE WATER Remove the spa cover and a...

Page 9: ...e and return to normal operation Temperature display is current after pump has been running for at least 2 minutes will appear solid on the display when the temperature is not current will alternate w...

Page 10: ...tructions Every 30 days Test reset GFCI per manufacturer s instructions Every 90 days Drain and refill spa per manufacturer s instructions Every 180 days Clean and condition cover per manufacturer s i...

Page 11: ...s installed press the Fiber button once to start the light and wheel press it again to stop the wheel and then again to turn the light off The fiber icon stands still when the fiber optic light is on...

Page 12: ...e spa s 2EAD THE INSTRUCTION MANUAL s DEQUATE DRAINAGE MUST BE PROVIDED IF THE EQUIPMENT IS TO be installed in a pit s OR USE ONLY WITHIN AN ENCLOSURE RATED 3 NCLOSURE s ONNECT ONLY TO A CIRCUIT PROTE...