Setup Changes with DIP Switch 1 ON
As soon as Switch #1 is placed
in the ON position,
The temperature will show
“T” after it instead of F or C,
indicating the System is
in Test Mode
1
S1
6
J17
J16
J29 VAC
J28 AUX FRZ
ON
DANGER! HIGH VOLTAGE WILL BE ACCESSIBLE!
SERVICE TECHNICIAN ONLY!
Move DIP Switch 1 (on S1 on the Logic circuit
board) to ON.
The system will enter Test Mode.
Moving DIP Switch 1 to OFF will exit Test Mode.
Read and understand these instructions before beginning this process.
Know the Setup Number you want before you power up the spa and wait to power up the spa until you’re ready to change
the Setup Number.
The system must be in Test Mode, so move Switch 1 to the ON position. The Test Menu will then be available.
Power up the spa, and press any button once to Link the panel. (Note: Switch 1 can be moved to the ON position immedi-
ately after power-up, if preferred - Danger! High Voltage will be present!)
You will have 1 minute
to complete the setup change after you manually exit Priming Mode. (Once familiar with the pro-
cess, the Setup change should take less than 15 seconds.)
When the panel displays RUN PMPS PURG AIR, press any Temperature button ONCE to exit Priming Mode.
You should see “---T” where the T indicates the system is in Test Mode.
Continued on Next Page.
READY
RANGE