Template 40941_J 04-02-10
56129-02/56130-02_97_B 04-16-12
17
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.
Setup Changes – Continued
SET
SET
The System will reset and go into Priming Mode if the Light Button
is pressed while anything other than the current setup is flashing.
If there is no change to the Setup Number (S-01, S-02, etc.),
the display returns to the SETP screen.
Several Setups can
exist in in this string
A dash (--) indicates the current Setup.
SET
SET
SET
SET
SET
SET
SET
While the Set Temperature is
still flashing, press Light
TEST will now appear in
the LCD first.
SET
RANGE
Main Screen
READY
RANGE FLTR1
Main Screen
READY
RANGE FLTR1
SET
Approx.
5 sec.
or
Approx.
5 sec.
or
SET
SET
SET
SET
When set to ON, Panel will display
alternate readings from
Senor A and Sensor B
on Main Screen
Displays Fault Log
Again,
You will have 1 minute
to complete the setup change after you manually exit Priming Mode.
Immediately after exiting Priming Mode, press this sequence of buttons: Warm*, Light, Warm, Warm, Warm, Warm. Continue
to press Warm until the diplay shows the Setup Number (S-01, S-02, etc.) you want to switch to. When the correct setup
number is showing, press Light once, and the system will reset, using the newly-selected Setup from that point on.
Move DIP Switch 1 to the OFF position to take the spa out of Test Mode. °F or °C will replace °T.
Using a permanent marker, write the Setup number on the Setup label mounted inside the system
lid (right). This is very important to any service person in the future who may need to replace a
circuit board or system and needs to change the Setup on a replacement part while in the fi eld.
NOTE: Changing the Setup may require wiring changes as well - refer to the wiring diagram or wiring
diagram addendum.
THIS SYSTEM IS
CONFIGURED AS
SETUP #
*If the Control Panel does not have a Warm (Up) button, but rather a single
Temp button, use the Temp button in place of the Warm button in the instruction
above. (The fl ow chart assumes a single Temperature Button.)
Indicates Flashing or Changing Segment
Key
A temperature button, used for “Action”
Light or dedicated “Choose” button, depending on control panel configuration
Indicates Alternating or Progressive Message - every 1/2 second
Waiting time - varies depending on function