Communications Options User’s Guide
65
Chapter 7. Foundation Fieldbus Communications
7. Foundation Fieldbus Communications
7.1
Optional Measurements
Foundation Fieldbus provides a means of communicating with the flowmeter. The patent numbers which apply are
5,909,363 and 6,424,872.
This Foundation Fieldbus device supports 6 Analog Input (AI) blocks, which can be configured to supply the following
measurements on the network (see Table 9 below).
Table 9: Available Measurements for the DF868
Channel 1
Units
Channel 2
Units
Average
Units
Ch1 Velocity
ft/s or m/s* Ch2 Velocity
ft/s or m/s* Avg Velocity
ft/s or m/s*
Ch1 Act Volumetric
VOL_U
Ch2 Act Volumetric
VOL_U
Avg Act Volumetric
VOL_U
Ch1 Std Volumetric
VOL_U
Ch2 Std Volumetric
VOL_U
Avg Std Volumetric
VOL_U
Ch1 Fwd Totals
TOT_U
Ch2 Fwd Totals
TOT_U
Avg Fwd Totals
TOT_U
Ch1 Rev Totals
TOT_U
Ch2 Rev Totals
TOT_U
Avg Rev Totals
TOT_U
Ch1 #Tot Digits**
none
Ch2 #Tot Digits**
none
Avg #Tot Digits
none
Ch1 Mass Flow
MASS_U
Ch2 Mass Flow
MASS_U
Avg Mass Flow
MASS_U
Ch1 Fwd Mass Totals
MTOT_U
Ch2 Fwd Mass Totals
MTOT_U
Avg Fwd Mass Totals
MTOT_U
Ch1 Rev Mass Totals
MTOT_U
Ch2 Rev Mass Totals
MTOT_U
Avg Rev Mass Totals
MTOT_U
Ch1 #Mass Tot Digits
none
Ch2 #Mass Tot Digits
none
Avg #Mass Tot Digits
none
Ch1 Timer
sec
Ch2 Timer
sec
Avg Timer
sec
Ch1 Error Code
none
Ch2 Error Code
none
Avg Error Code
none
Ch1 SSUP
none
Ch2 SSUP
none
Avg SSUP
none
Ch1 SSDN
none
Ch2 SSDN
none
Avg SSDN
none
Ch1 Sound Speed
ft/s or m/s* Ch2 Sound Speed
ft/s or m/s* Avg Sound Speed
ft/s or m/s*
Ch1 Density***
see note
Ch2 Density***
see note
Ch1 Temperature
Deg F or C*
Ch2 Temperature
Deg F or C*
Ch1 Pressure
PRESS_U
Ch2 Pressure
PRESS_U
*Metric or English units are determined by the setup of the flowmeter.
**Totalizer digits are available for informational purposes only. Respective totals are automatically scaled by the Tot
Digits value selected in the flowmeter setup.
***If the meter is outputting Mole Weight, the unit is “mw”, otherwise it is the programmed pressure unit.
VOL_U, TOT_U, MASS_U, MTOT_U and PRESS_U are determined by the units chosen for these measurements in the
flowmeter setup. See the instrument User's Manual for the setup of these parameters.