APPENDIX D
SCREEN DESCRIPTION FOR ENGINEERING UNIT MENU
↓
ENG:%
Validate by pressing the * to enter the sub-menu related to the level variable setting in
engineering units.
UNIT:%
Validate by pressing the
* to select the desired engineering unit (%, cm, m, inch…) used to express
the level variable. Generally, the engineering unit is in %.
##.###
DECIMALS
Validate by pressing the * to set the number of decimals after the dot.
L
OWER
R
EFERENCE
V
ALUE
Validate by pressing the * to set the lower level value expressed in industrial unit corresponding
to the Low Reference (REF L). Always set at 0 if unit is %. Value ranges from 0 to value of UPPER
REFERENCE VALUE.
U
PPER
R
EFERENCE
V
ALUE
Validate by pressing the * to set the higher level value expressed in industrial unit corresponding
to the High Reference (REF H). Always set at 100 if unit is %. Value ranges from LOWER
REFERENCE VALUE to 9999.9.
SAVE
Validate by pressing the * to start the saving procedure of parameters previously entered in the
instrument memory.
↑
BACK
Return to previous menu.
SCREEN DESCRIPTION FOR FILTERING MENU
FILTERING
Validate by pressing the * to check the Filtering data.
DAMPING
Validate by pressing the * to check the Damping data.
DAMPI
NG
ON
Indicates first order Filtering function is activated.
DAMPI
NG
OFF
Indicates first order Filtering function is not activated.
DAMPING:s
Indicates damping value adjusted in the Advanced Setup menu.
↑
BACK
Return to previous menu.
SMART F
I
LT
ERING
Validate by pressing the * to check the Smart Filtering parameters.
S
MART
F
I
LT
ERING
ON
Indicates the Smart Filtering function is activated.
S
MART
F
I
LT
ERING
OFF
Indicates the Smart Filtering function is not activated.
W
INDOW of
INT
E
G
RATION : s
Indicates the Window of Integration value adjusted in the Advanced Setup menu.
D
EAD
Z
ONE of
INT
E
G
RATION : %
Indicates the Dead Zone of Integration value adjusted in the Advanced Setup menu.
W
INDOW of
VAL
IDATION
Indicates the Window of Validation value adjusted in the Advanced Setup menu.
↑
BACK
Return to previous menu.
Summary of Contents for Masoneilan 12400 Series
Page 46: ...44 BHGE 2017 Baker Hughes a GE company All rights reserved...
Page 62: ...60 BHGE 2017 Baker Hughes a GE company All rights reserved APPENDICES...
Page 68: ...66 BHGE 2017 Baker Hughes a GE company All rights reserved APPENDIX C see following pages...
Page 72: ...70 BHGE 2017 Baker Hughes a GE company All rights reserved APPENDIX D see following pages...