![Bailey platinum standard PTSP Series Product Instruction Download Page 17](http://html1.mh-extra.com/html/bailey/platinum-standard-ptsp-series/platinum-standard-ptsp-series_product-instruction_467168017.webp)
INTRODUCTION
SPECIFICATIONS
1 - 8
WBPEEUI110506A0
Temperature limits for
electronics, cell, and
optional liquid crystal
display
Supply voltage
12 to 53 VDC (12 to 42 VDC for CSA certified applications)
4,5
. Installation category III.
Power supply effect
Analog mode
±0.005% of URL per volt
Digital field bus mode ±0.003% of URL per volt
Output signal
Analog
4 to 20 mA
Digital
Bailey FSK communications
Output current limiting
Maximum
≥
21.6 mA
Minimum
≤
3.7 mA
Loop load limits
Refer to Figure
Damping/response
time (one time con-
stant - approximately
62% of final reading)
Analog and digital response to a step input change is adjustable from 0.0 to
32.0 secs and is entered during configuration. This value is in addition to:
Cell response time: dependent on cell and fill fluid
Electronics response time: approximately 0.3 sec
RFI/EMI effects
≤
±0.1% of URL in fields from 4 to 1,000 MHz at 10 V/m
Surge tolerance
Complies to IEEE 472 test criteria. 2.5 kV, 1.5 MHz at 10 V/m
Vibration effect
±0.1% of URL for 1 g from 1 to 2,000 Hz in any axis of the transmitter
Enclosure rating
NEMA 4X and IP67
FM/CSA
certifications
6,7
Explosionproof and
dust-ignitionproof
Class I, Division 1, Groups B, C and D; Class II, Division 1, Groups E, F and G;
Class III
Intrinsically safe
Classes I, II and III, Division 1; applicable groups when connected per drawing
B222611
Nonincendive
Class I, Division 2, Groups A, B, C and D; Class II, Division 2, Groups E, F and G;
Class III
NOTES:
1. The normal operating temperature range is that at which the transmitter meets all specifications. The extreme operating temperature
range is that at which the transmitter remains powered without damage.
2. All transmitters with fluorinated oil filled cells can only be operated in temperatures from -10° to +80°C (+14° to +176°F).
3. The normal operating temperature range for the LCD is that at which the LCD remains functional. Exceeding those conditions may cause
the LCD to go blank. The transmitter remains functional to its operating limits. When the temperature returns to the acceptable range, the
display is restored; however, the life of the display may be reduced.
4. The minimum supply voltage necessary to support communications is 17.0 VDC.
5. Add 0.4 VDC to all minimum supply voltage values if using the lightning arrestor option.
for the ambient condition limits for certified applications.
7. The transmitters are only certified for those agencies and classes indicated on the certification label. Do not install the transmitters in
locations for which they are not suited. Refer to nomenclature position 12.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
Table 1-3. Common Specifications
(continued)
Property
Characteristic/Value
Parameter
Electronics
1
Cell
1,2
LCD
3
°C
°F
°C
°F
°C
°F
Normal
operating
-40 to +85 -40 to +185
-40 to +85
-40 to +185
0 to +50
+32 to +122
Extreme
operating
-50 to +85 -58 to +185 -50 to +120 -58 to +248
0 to +50
+32 to +122
Storage/
transport
-55 to +85 -67 to +185
-55 to +85
-67 to +185 -20 to +70
-4 to +158
Summary of Contents for platinum standard PTSP Series
Page 1: ......