![Bailey platinum standard PTSP Series Product Instruction Download Page 18](http://html1.mh-extra.com/html/bailey/platinum-standard-ptsp-series/platinum-standard-ptsp-series_product-instruction_467168018.webp)
INTRODUCTION
SPECIFICATIONS
WBPEEUI110506A0
1 - 9
Type PTSPG Gage Pressure Transmitter Specifications
Table
lists the specifications unique to Type PTSPG gage
pressure transmitters.
Table 1-4. Ambient Condition Limits for Certified Applications
Agency
Category
T
max
T
min
P
max
P
min
O
2max
°C
°F
°C
°F
kPa
psia
kPa
psia
%
FM
Explosionproof
80
176
-40
-40
108
15.7
86
12.5
21
Dust-ignitionproof
Intrinsic safety
65 (T4)
149 (T4)
Nonincendive
CSA Explosionproof
60
140
Dust-ignitionproof
Intrinsic safety
40 (T3C)
60 (T3A)
104 (T3C)
140 (T3A)
Nonincendive
60 (T4A)
140 (T4A)
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
Table 1-5. Type PTSPG Gage Pressure Transmitter Specifications
Property
Characteristic/Value
Measurement range,
turndown ratio, zero sup-
pression, and zero
elevation
Lower range value (zero) and upper range value (100%) can be calibrated at any
value of pressure, provided that:
1. Their algebraic difference (the calibrated span) corresponds to an
authorized TDR.
2. Both are within the following acceptable limits.
Stability
PTSPGF
±0.2% of URL per 12-month period (at reference conditions)
PTSPGG and PTSPGJ
±0.1% of URL per 12-month period (at reference conditions)
Type
International System Units
Range Limits
1
(kPa)
Span and Turndown Ratio (TDR)
Upper
Lower
Nominal (kPa)
Minimum (kPa)
PTSPGF
690
-100
690
1:1 TDR
69
10:1 TDR
PTSPGG
3,000
0
3,000
1:1 TDR
200
15:1 TDR
PTSPGJ
40,000
0
40,000 1:1 TDR
1,000
40:1 TDR
Type
American Units
Range Limits
1
(psi)
Span and Turndown Ratio (TDR)
Upper
Lower
Nominal (psi)
Minimum (psi)
PTSPGF
100
-14
100
1:1 TDR
10
10:1 TDR
PTSPGG
450
0
450
1:1 TDR
30
15:1 TDR
PTSPGJ
5,800
0
5,800
1:1 TDR
145
40:1 TDR