1 DISPLAY (DP C07.UART)
1.1 Specifications and Parameters of the Display
•
36V / 43V / 48V Power Supply;
• Rated Current: 10 mA
• Maximum Operating Current: 30 mA
• Power-off Leakage Current: <1uA
•
Operating Current Supplied to the Controller: 50 mA
•
Operation Temperature: -18 ~ 60 %
•
Storage Temperature: -30~70 %
• Waterproof Grade: IP65
•
Storage Humidity: 30 % – 70 %
1.2 Appearance and Dimensions
1.2.1
Materials and Dimensions
•
The shell is made of PC. The liquid crystal display is made of hardened PMMA.
DISPLAY (DP CO7.UART)
1.3 Function Overview and Key Definitions
1.3.1
Function Overview
•
Use of a two-way serial communication protocol,
simple operation of the display via the external
5-key keypad.
•
Speed display: displaying the real-time speed as
SPEED, the maximum speed as MAXS and the
average speed as AVG.
•
km or mile: The user can choose between km
and mile.
•
Intelligent battery level indication: With an
optimization algorithm, a stable display of the
battery level is ensured, and the problem of fluc-
tuant battery level indication common with other
displays is avoided.
•
Automatic light-sensitive lights: The headlight,
taillight and display light will be automatically
turned on/ off depending on lighting conditions.
•
5 levels off display backlighting: Different levels
•
5-Level-Support: setting power Levels 1 to 5
•
Trip distance indication: The maximum distance
displayed is 99999. Single-trip distances TRIP or
the total distance TOTAL can be displayed.
•
Display of error messages
•
Walk assistance
•
Settings: Various parameters, e.g. mode, wheel
diameter, speed limit etc., can be set on the com
puter via a communication cable. See the setting
•
Maintenance warning (this function can be deac
-
tived): Maintenance warning information is dis
-
played based on battery charge cycles and riding
distance. The display automatically estimates the
battery life and gives warnings when the number
of charge cycles exceeds the set value. A warning
will also be displayed when the accumulated total
riding distance exceeds the set value.
1.3.2
Information on the Display
A
Maintenance warning: When there is a need for
maintenance the symbol
will be dis
-
played (riding distance or the number of battery
charge cycles exceed the set value, function can
be deactivated)
B
Menu
C
Speed display: display of the speed, km/h or mph
D
Speed mode: average speed (AVG km/h), maxi
-
mum speed (MAXS km/h)
E
Error display: When a fault is detected the
symbol
will be displayed.
F
Distance indication: display of the distance
depending on the setting.
G
Level indication: The chosen level 1–5 will be
displayed; if there is no numeric display, it means
that there is no assistance (by the motor). If the
rider is walking and pushing the e-bike,
will
be displayed.
H
Walk assistance
I
Headlight indication: only shows when headlight
or backlight are on
CONSUMER MANUAL
MAX DRIVE SYSTEM
CONSUMER MANUAL
MAX DRIVE SYSTEM
8