Cast Iron Pipe, Standard Classes, 3…10 inch
Size
in.
Class
in.
A
B
C
D
E
F
G
H
3
OD
3 80
3 96
3 96
3 96
—
—
—
—
Wall
0 39
0 42
0 45
0 48
ID
3 02
3 12
3 06
3 00
4
OD
4 80
5 00
5 00
5 00
—
—
—
—
Wall
0 42
0 45
0 48
0 52
ID
3 96
4 10
4 04
3 96
6
OD
6 90
7 10
7 10
7 10
7 22
7 22
7 38
7 38
Wall
0 44
0 48
0 51
0 55
0 58
0 61
0 65
0 69
ID
6 02
6 14
6 08
6 00
6 06
6 00
6 08
6 00
8
OD
9 05
9 05
9 30
9 30
9 42
9 42
9 60
9 60
Wall
0 46
0 51
0 56
0 60
0 66
0 66
0 75
0 80
ID
8 13
8 03
8 18
8 10
8 10
8 10
8 10
8 00
10
OD
11 10
11 10
11 40
11 40
11 60
11 60
11 84
11 84
Wall
0 50
0 57
0 62
0 68
0 74
0 80
0 86
0 92
ID
10 10
9 96
10 16
10 04
10 12
10 00
10 12
10 00
Table 4: Cast iron pipe, standard classes, 3…10 inch
PARTS AND ACCESSORIES
Couplant
Part Number
Description
D002-2011-001
Dow Corning® Molykote® 111 Grease; 5 3 oz Tube; 150° F (65° C)
D002-2011-002
Dow Corning 732; Permanent Mount; 356° F (180° C)
Dow 111 grease is included with transducers
Power Supplies
Part Number
Description
68334-001
Wall Plug; 100…264V AC In; 24V DC Out; -20…50° C
68334-002
Module; 85…264V AC In; 24V DC Out; -30…70° C
For ordering transducers and transmitter separately, please contact factory
Transit Time Ultrasonic Flow Meters, TFX-500w Clamp-On Meter
www.badgermeter.com
Dynasonics, AquaCUE and SoloCUE are registered trademarks of Badger Meter, Inc Other trademarks appearing in this document are the property of their respective entities Due
to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent
an outstanding contractual obligation exists © 2021 Badger Meter, Inc All rights reserved
Control. Manage. Optimize.