Units Submenus
Options/Descriptions
DISPLAY MODE
Select whether to display the flow rate, flow total, velocity or both flow rate and flow total on the display
Alternatively, you can change the display from the
Home Screen
by pressing the
DOWN
button
*FLOW RATE
FLOW TOTAL
VELOCITY
FLOW/TOTAL
Setup > Meter
An asterisk (*) indicates the parameter default
Meter Submenus
Options/Descriptions
TRANSDUCER
Select the transducer type:
DTTSU 2 MHZ
Option UZ when ordered with the TFX-500w meter
DTTS/DTTC 2 MHZ
Options CA…CS and CZ when ordered with the TFX-500w meter
DTTJ/K EASYRAIL 1 MHZ
Options JZ and KZ when ordered with the TFX-500w meter
DTTN/DTTR 1 MHZ
Options NZ, WZ and RZ when ordered with the TFX-500w meter
MOUNTING
For mounting options, see the transducer user manual
Z PATH
*V PATH
W PATH
DTTS/DTTC TYPE
DTTS/DTTC TYPE
is substituted for
MOUNTING
when
TRANSDUCER DTTS/DTTC
is selected as the transducer type
CA: 1/2 IN ANSI
CJ: 1-1/4 IN COPPER
CB: 3/4 IN ANSI
CK: 1-1/2 IN COPPER
CC: 1 IN ANSI
CL: 2 IN COPPER
CD: 1-1/4 IN ANSI CM: 1/2 IN SS TUBE
CE: 1-1/2 IN ANSI CN: 3/4 IN SS TUBE
CF: 2 IN ANSI
CP: 1 IN SS TUBE
CG: 1/2 IN COPPER CQ: 1-1/4 IN SS TUBE
CH: 3/4 IN COPPER CR: 1-1/2 IN SS TUBE
CT: 1 IN COPPER CS: 2 SS IN TUBE
Parameter Descriptions by Menu
Page 19
May 2021
TTM-UM-02537-EN-06